Manual of instructions TT-181 9/33
Temperature Controller MP-888
ON/OFF-Switch unit (green)
ON/OFF-Switch heating (green)
Water: Switchable in stages 3 kW + 6 kW = 9 kW
Oil: 3 kW (OR-circuit)
ON/OFF-Switch horn (green)
Temperature monitoring internal left (red)
The maximum temperature of the unit is exceeded. The unit switches off.
Control lamp Temperature deviation control right (red)
Difference between desired and actual temperature is too big. Unit continues to run.
Control lamp thermal relay pump (red)
Thermal relay of the pump motor has responded.
Mould drainage (green)
- Cooling the unit below 60°C
- Switch the unit off by the green ON/OFF-Switch
- Changeover switch for pump operation mode to position „Vacuum“
- Press the green button approx 5 sec.
Change-over switch for pump operation mode (red)
Pressure for pressure operation (normal operation)
Vacuum for leakstopper operation and mould drainage
Level control lamp pre-warning (yellow)
lights + horn Unit continues to run, level has to be corrected
Level control lamp (yellow)
lights + horn unit switches off
Main switch
Emergency stop
Name plate with following details:
Switch cabinet – safety device