5.8- ELECTRICAL CONNECTIONS
THE ELECTRIC CONNECTION OF THE ACTUATOR CAN BE PERFORMED ONLY BY
COMPETENT AND QUALIFIED TECHNICAL PERSONNEL SATISFYING THE
TECHNICAL AND PROFESSIONAL REQUIREMENTS FORESEEN BY THE LAW IN
FORCE IN THE COUNTRY OF INSTALLATION ISSUING TO THE CUSTOMER A
DECLARATION OF CONFORMITY FOR THE CONNECTION AND/OR THE PLANT
PERFORMED.
BEFORE PERFORMING THE ELECTRIC CONNECTION OF THE FEEDING UNIT,
VERIFY THE CORRECT INSTALLATION OF THE MOTORS (ACTUATORS).
THE MAINS TO WHICH THE FEEDING UNIT IS CONNECTED MUST COMPLY WITH
THE REQUIREMENTS OF THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION,
AS WELL AS SATISFY THE TECHNICAL FEATURES GIVEN IN TAB.1 AND THE
RATING PLATE (PAR.3.1).
THE SECTION OF THE MAINS CABLES MUST BE PROPERLY SIZED ACCORDING TO
THE ABSORBED ELECTRIC POWER (SEE RATING PLATE AND "CE" MARKING).
ANY TYPE OF ELECTRIC MATERIAL (PLUG, CABLE, TERMINALS, ETC.) USED FOR
THE CONNECTION MUST BE SUITABLE FOR THE USE, WITH "CE" MARKING, AND
COMPLYING WITH THE REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN
THE COUNTRY OF INSTALLATION.
TO GUARANTEE AN EFFICACIOUS SEPARATION OF THE POWER ELECTRIC
SYSTEM IT IS COMPULSORY TO INSTALL AT THE SOURCE OF THE MACHINE A
SWITCH (BUTTON) BIPOLAR QUALITY APPROVED WITH A CONTACT OPERING OF
AT LEAST 3mm.
THE FEEDING AND CONTROL UNITS MOD.TF24R CAN BE SUPPLIED ALSO BY A 24V
DC EXTERNAL SOURCE BY MEANS OF THE "ORIGINAL TOPP" FEEDER MOD. AL/TF
WITH BUFFER BATTERIES. IN THIS CASE, THE CONNECTION HAS TO BE
PERFORMED ON THE SUITABLE TERMINAL BOARD (M2) OF THE ELECTRONIC
CARD OF THE FEEDING AND CONTROL UNIT.
19
TF24R/44R
INSTALLATION AND USE INSTRUCTIONS
5- INSTALLATION