EasyManua.ls Logo

Tormatic T100 R - Page 28

Tormatic T100 R
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26-EN T100 R
Menu5 Various settings
Menu
item
Entry Selection
51 Function of external control devices
0 Off (default setting)
1 Dead man open/ dead manclose
2 Pulseopen/ dead manclose
3 Pulseopen/ pulseclose
4 Pulse1/2door opening/ pulseclose
5 AR operation, automatic closing
6 AR operation,1/2door opening
7 Open/close operation
8 Open/close pulse as NO contact
52 001-256 Entry of control address
53 Door control module
0 off (default setting)
1, 2, 3, 4 DC module
5 RadioSafe module, wireless closing edge (op-
tional)
6, 7 reserved
55 Door setting for smoke and heat extraction
system position
- - Exit menu
Menu6 Radio
Menu
item
Entry Selection
60 Programming the start button on the hand-held
transmitter
61 Programming the 1/2 opening button on the hand-
held transmitter
62 Programming the light button on the hand-held
transmitter
63 Deleting radio codes
Press for 5s
64 Deleting radio codes
0 off (default setting)
1 Pulsed operation open/stop/close
2 Automatic closing AR
3 Open/close operation
- - Exit menu
Menu7 drive settings
Menu
item
Entry Selection
70 Soft start with reduced torque
0 Off
1 - 13 Time 60ms - 300ms (in steps of 20ms)
71 0 - 40 Deceleration path before reaching upper end
position incm (10cm = default setting)
72 0 - 20 Reduced torque (16 = default setting)
- - Exit menu
Menu9 Service menu
menu
item
Entry Selection
90 Selection of the door maintenance cycle
0 No service interval (default setting)
1 10000 cycles
2 20000 cycles
3 30000 cycles
4 40000 cycles
5 50000 cycles
6 60000 cycles
7 80000 cycles
8 100000 cycles
9 120000 cycles
10 150000 cycles
11 200000 cycles
12 250000 cycles
91 Cycle counter output door cycles
96 Operating hours counter output – hours
97 Error memory output hours – error code
98 Software version output – serial number – creation
date
99 Reset to default setting
Press for 5s
- - Exit menu
Diagram for door run and recommended settings
71
70
72
Speed
Time
Menu7 Recommended settings
Menu item
SI 4,5.90
SI 8.120
SI 20.90
SI 35.60
70 Soft start acceleration time 5 0 8 7
71 Soft stop 20 25 20 20
72 Reduced torque 15 0 10 10

Table of Contents