EN-25T100 R
6 Program overview
Menu3 Basic settings
Menu
item
Entry Selection
30 Door setting of upper end position
Reversal of the direction (press for 5s)
31 Door setting of lower end position
32 Door setting for 1/2 opening position
33 Fine correction of upper end position
50 Factory settings
50 - 0 0...80mm lower
50 - 99 0...80mm higher
34 Fine correction of lower end position
50 Factory settings
50 - 0 0...80 mm lower
50 - 99 0...80mm higher
35 Selection of closing edge safety device
Measurement display (press 5seconds)
0 Optical closing edge safety device OSE
1 Electrical safety edge8K2 (default setting)
2 Pressure wave switch with testing
3 Electrical safety edge8K2 with slack rope
switch
4 Wireless closing edge, RadioBand
36 Selection of photoelectric sensor
0 Without photoelectric sensor (default setting)
1 2-wire photoelectric sensorLS2
2 4-wire photoelectric sensorLS5 photoelectric
reflection sensor
3 Photoelectric sensorLS2, mounted in frame
4 Photoelectric sensorLS5 photoelectric
reflection sensor mounted in frame
5 Light grid with testing (SG14)
37 Correction of pre-limit switch closing edge safety
25 Correction of pre-limit switch closing edge
safety (default setting)
25 - 0 0...50 mm lower
25 - 99 0...100 mm higher
38 Response of photoelectric sensor
0 No reduced open time (default setting)
1 Reduced open time with AR operation
- - Exit menu
Menu4 Further door settings
Menu
item
Entry Selection
40 Selection of operating mode
0 Dead man OPEN / dead man CLOSE
1 Pulse OPEN / dead man CLOSE
2 Pulse OPEN / pulse CLOSE (default setting)
3 AR - automatic closing
41 Response to closing edge safety device
0 Full reversing (default setting)
1 Partial reversing
Menu4 Further door settings
Menu
item
Entry Selection
44 Hold-open time in seconds
0 0s (default setting)
1 - 30 1s - 30s (in increments of 1s)
31 - 60 35s - 180s (in increments of 5s)
61 - 99 190s - 22.5min (in increments of 30s)
45 Status relayX5
0 Door close signal (default setting)
1 Door open signal
2 Status of door for traffic light controlA800
3 2-minute garage light
4 5-minute garage light
5 On/ off with hand-held transmitter (menu
item62)
6 ELTACO wipe pulse
46 Status relayX6
0 Door close signal
1 Door open signal (default setting)
2 Status of door for traffic light controlA800
3 Locking
4-14 Warning light closing (0- 10s warning time)
15-25 Warning light opening and closing (0s - 10s)
49 Motor duty cycle
0 Without limitation (default setting)
1 Geared motor 5.24 (25min / 35%)
2 Geared motor 5.24 WS (25min / 30%)
3 Geared motor 9.15, 9.20, 9.24 (25min / 60%)
4 Geared motor 9.24 WS (25min / 20%)
5 Geared motor 6.65 DU (10min / 35%)
6 Geared motor 14.15 (25min / 60%)
- - Exit menu
Menu5 Various settings
Menu
item
Entry Selection
50 Key switch function (J7)
0 Pulse input OPEN/CLOSE (default setting)
1 Inhibit control panel
2 Inhibit external control elements
3 Inhibit control panel and external control
elements
4 Activate control elements for 10seconds
5 Switch-over to dead man mode for closing
6 Switch-over to 1/2opening (winter mode)
7 Pulse input OPEN-STOP-CLOSE
8 Pulse input 1/2 OPEN-STOP-CLOSE
9 Automatic closing AR
10 Pulse input for smoke and heat extraction sys-
tem (setting in menu item55)
11 Pulse input for smoke and heat extraction sys-
tem, inverted (setting in menu item55)
12 Mutual locking of door

Table of Contents