EN-25T100 R
6 Program overview
Menu3 Basic settings
Menu
item
Entry Selection
30 Door setting of upper end position
Reversal of the direction (press for 5s)
31 Door setting of lower end position
32 Door setting for 1/2 opening position
33 Fine correction of upper end position
50 Factory settings
50 - 0 0...80mm lower
50 - 99 0...80mm higher
34 Fine correction of lower end position
50 Factory settings
50 - 0 0...80 mm lower
50 - 99 0...80mm higher
35 Selection of closing edge safety device
Measurement display (press 5seconds)
0 Optical closing edge safety device OSE
1 Electrical safety edge8K2 (default setting)
2 Pressure wave switch with testing
3 Electrical safety edge8K2 with slack rope
switch
4 Wireless closing edge, RadioBand
36 Selection of photoelectric sensor
0 Without photoelectric sensor (default setting)
1 2-wire photoelectric sensorLS2
2 4-wire photoelectric sensorLS5 photoelectric
reflection sensor
3 Photoelectric sensorLS2, mounted in frame
4 Photoelectric sensorLS5 photoelectric
reflection sensor mounted in frame
5 Light grid with testing (SG14)
37 Correction of pre-limit switch closing edge safety
25 Correction of pre-limit switch closing edge
safety (default setting)
25 - 0 0...50 mm lower
25 - 99 0...100 mm higher
38 Response of photoelectric sensor
0 No reduced open time (default setting)
1 Reduced open time with AR operation
- - Exit menu
Menu4 Further door settings
Menu
item
Entry Selection
40 Selection of operating mode
0 Dead man OPEN / dead man CLOSE
1 Pulse OPEN / dead man CLOSE
2 Pulse OPEN / pulse CLOSE (default setting)
3 AR - automatic closing
41 Response to closing edge safety device
0 Full reversing (default setting)
1 Partial reversing
Menu4 Further door settings
Menu
item
Entry Selection
44 Hold-open time in seconds
0 0s (default setting)
1 - 30 1s - 30s (in increments of 1s)
31 - 60 35s - 180s (in increments of 5s)
61 - 99 190s - 22.5min (in increments of 30s)
45 Status relayX5
0 Door close signal (default setting)
1 Door open signal
2 Status of door for traffic light controlA800
3 2-minute garage light
4 5-minute garage light
5 On/ off with hand-held transmitter (menu
item62)
6 ELTACO wipe pulse
46 Status relayX6
0 Door close signal
1 Door open signal (default setting)
2 Status of door for traffic light controlA800
3 Locking
4-14 Warning light closing (0- 10s warning time)
15-25 Warning light opening and closing (0s - 10s)
49 Motor duty cycle
0 Without limitation (default setting)
1 Geared motor 5.24 (25min / 35%)
2 Geared motor 5.24 WS (25min / 30%)
3 Geared motor 9.15, 9.20, 9.24 (25min / 60%)
4 Geared motor 9.24 WS (25min / 20%)
5 Geared motor 6.65 DU (10min / 35%)
6 Geared motor 14.15 (25min / 60%)
- - Exit menu
Menu5 Various settings
Menu
item
Entry Selection
50 Key switch function (J7)
0 Pulse input OPEN/CLOSE (default setting)
1 Inhibit control panel
2 Inhibit external control elements
3 Inhibit control panel and external control
elements
4 Activate control elements for 10seconds
5 Switch-over to dead man mode for closing
6 Switch-over to 1/2opening (winter mode)
7 Pulse input OPEN-STOP-CLOSE
8 Pulse input 1/2 OPEN-STOP-CLOSE
9 Automatic closing AR
10 Pulse input for smoke and heat extraction sys-
tem (setting in menu item55)
11 Pulse input for smoke and heat extraction sys-
tem, inverted (setting in menu item55)
12 Mutual locking of door