26
3. MACHINE WON’T DISPENSE WATER
1. First, when this issue occurs, check the solution tank sight gage for water level. If empty, ll the tank with
cleaning solution.
2. Check the solution ow adjustment knob and ensure that the knob is adjusted to the solution ow level
you desire.
3. If there is solution in the sight gage and the solution ow adjustment knob is properly positioned, then
the lter is likely clogged with debris and needs to be cleaned. Start by draining the solution tank. Unscrew
the inline lter, located on the underside of the unit between the wheels and the casters, and clean out the
debris. Once clean, re-attach the lter and tighten it until snug. Ensure the screen lter element is aligned
properly with the body of the lter during reassembly. Fill the solution tank and check for solution ow. If
solution is owing, you’ve identied the issue and you can return to cleaning.
4. Check the wire connections to the valve.
If none of the actions listed above x the solution ow, contact your distributor or Tornado for technical
support.
Sight gage hose
Inline lter screen
Inline lter cap
Sight gage hose
3
4
Solution ow adjustment knob and
wire connections
2
Check sight gage hose for
solution level
1

Related product manuals