38 (64)
MAINTENANCE OPERATIONS
TKU--- C 01140--- 1 EN 0404
D
DD
D Check oscillating axle tight en ing torques
Bolt tightness (dry)
M 12 ( 8.8) bolts 80 Nm....
M 16 ( 8.8) bolts 210--240 Nm....
3.6. Every 1000 hours
D
DD
D Inspect the cooling system
Pressurize the cooling system and ensure
that there are no leaks.
D
DD
D Check engine crankcase pressure
Check and record the crankcase pressure.