InstallingtheRotorAssembly
1.Installtherotorassemblywiththe2bearing
guardsandbearingsusing4locknuts(5/8inch),
4washers,and4bolts(5/8x2-1/2inches)for
bothsetsofguardsandbearings(Figure9).
Torquetheboltsto183to224N∙m(135to165
ft-lb).
2.Using4nuts(9/16inch),installtherotormount
andmotor(Figure8).T orquethenutsto127to
157N∙m(94to116ft-lb).
3.Securethedriveadaptertotherotorassembly
usinganut(5/8inch)andbolt(5/8x4inches)
asshowninFigure7.Torquetheboltto183to
224N∙m(135to165ft-lb)
CheckingtheHydraulic
Lines
ServiceInterval:Beforeeachuseordaily
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.Fluidinjected
intotheskinmustbesurgicallyremoved
withinafewhoursbyadoctorfamiliarwith
thisformofinjury;otherwise,gangrenemay
result.
•Keepyourbodyandhandsawayfrom
pinholeleaksornozzlesthateject
high-pressurehydraulicuid.
•Usecardboardorpapertondhydraulic
leaks;neveruseyourhands.
Storage
1.Beforelong-termstorage,washtheattachment
withmilddetergentandwatertoremovedirtand
grime.
2.Paintallscratchedorbaremetalsurfaces.
Note:PaintisavailablefromyourAuthorized
ServiceDealer.
3.Storetheattachmentinaclean,drygarageor
storagearea.Coverittoprotectitandkeepit
clean.
Important:Storethetilleronapalletor
concrete.Donotstoreitontheground.
10