EasyManua.ls Logo

Toro 30344 - Page 136

Toro 30344
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ImplementReliefPressureTest(UsingPressureGauge)(Machine
SerialNumbersbelow316000000)(continued)
Note:Iftheimplementreliefpressureis4,820to6,900kPa(700to1,000
psi)andasteeringorliftproblemoccurs,inspectforaproblemunrelatedto
thehydrauliccircuit(e.g.,bindingsteeringorliftsystemcomponents,debris
build-upon/underthecuttingdeck).Checkandrepairotheritemsbefore
continuingwithhydraulictests.
4.Iftheimplementreliefpressureisbelow4,820kPa(700psi),adjustthe
implementreliefvalveinthetransmissionbyaddingtherequiredamount
ofshimsfromtheshimpack;refertoImplementReliefValveinthe
Sauer-Danfoss(Sundstrand)15SeriesServiceManualattheendofthis
chapter.
Note:Forevery0.254mm(0.010inch)ofshimthickness,thereisan
approximate340kPa(50psi)changeinimplementreliefpressure.
Ifaddingshimstothereliefvalvedoesnotincreasepressure,inspectthe
conditionofthechargepumpgerotorandinternalhousing;refertoCharge
PumpServiceintheSauer-Danfoss(Sundstrand)15SeriesServiceManual
attheendofthischapter.
Ifthechargepumpisingoodcondition(noscoring,scratches,orexcessive
wear),thegeneralconditionofthetransmission’spistonpumpandpiston
motormightbesuspectedofwearandinefciency.Alackofminimum
implementreliefpressurecouldbeduetothechargepumphavingtodirect
allowtothemaintractioncircuit(pistonpumpandpistonmotor).
5.Disconnectpressuregaugefromthetransmission.Installpipeplugbackin
thetransmission.Checkhydraulic-uidlevelinreservoir(frontaxle).
HydraulicSystem:TestingtheHydraulicSystem
Page5–52
Groundsmaster
®
3280-D/3320
05138SLRevB

Table of Contents