g027517
Figure61
7.Disposetheusedoilatarecyclingcenter.
ServicingtheSparkPlug
ServiceInterval:Every200hours—ForKohler
engines—checkthesparkplug(s).
Every500hours—ForKohlerengines—replace
thesparkplug(s).
Type:ChampionXC12YC
AirGap:0.76mm(0.03inch)
RemovingtheSparkPlug
1.Parkthemachineonalevelsurface,disengage
theblade-controlswitch,andengagetheparking
brake.
2.Shutofftheengine,removethekey,andwait
forallmovingpartstostopbeforeleavingthe
operatingposition.
3.Removethelefthydraulic-unitshroudinthe
orderlistedwithFigure62.Thisgivesyou
accesstothefrontsparkplug.
g009922
g009919
Figure62
1.Pullthistabouttothe
sideinthedirectionofthe
arrow
3.Pulltheshroudoffthis
frametabinthedirection
ofthearrow
2.Pulltheshroudoffthis
frametabinthedirection
ofthearrow
4.Shroud
4.Removethesparkplug.
g008803
g027478
Figure63
45