g229108
Figure44
BeforeStarting(uidcold)
1.Fillerplug5.Warningbuzzer—no
sound
2.Fillerneck
6.Fluidlevel(cold)
3.Overowtube7.Solenoid-returnvalve
(open)
4.Leak-detectortank8.Floatswitch
(raised—open)
g229109
Figure45
NormalOperation(uidwarm)
1.Fluidlevel(warm)
3.Warningbuzzer
2.Solenoid-returnvalve
(closed)
4.Floatswitch
(raised—open)
g229110
Figure46
LeakAlert!
1.Floatswitch
(down—closed)
Fluidleveldown118
to177ml(4to6oz)
3.Fluidlevel(warm)
2.Warningbuzzer
CheckingtheSystemOperation
1.WithignitionswitchintheONposition,movethe
leakdetectorswitchrearwardandhold.After
the1-seconddelayelapses,thealarmshould
sound.
2.Releasetheleak-detectorswitch.
Checkingthe
Leak-Detector-SystemOperation
1.MovetheignitionswitchtotheONposition.Do
notstarttheengine.
2.Removethehydraulic-tankcapfromtheneck
ofthetank.
3.Insertacleanrodorscrewdriverintothetank
neckandgentlypushdownontheoatswitch
(Figure47);thealarmshouldsoundafterthe
1-seconddelay.
44