Greensmaster 3320/3420Page 6 -- 12Electrical System
InfoCenter Display (Serial Number Above 312000000)
The InfoCenter Display used on TriFlex Hybrid
Greensmowerswith serialnumber above312000000is
a LCD device that is located on the console. The Info-
Center provides information for the machine operator
during machine operation, provides electrical system
diagnostic assistance for technicians and allows inputs
for adjustable m achine settings.
PowerfortheInfoCenterisavailablewhenenergizedby
the TEC controller (key switch in the START or RUN
position).ACAN--bussysteminvolvingtheTECcontrol-
ler, the generator, the cutting unit motors and the Info-
Center is used to provide necessary machine
communication for InfoCenter operation.
Splash Screen
The InfoCenter splash screen (Fig. 16) is displayed
when the key switch is initially turned to the RUN or
START position. The splash screen allows basic ma-
chine information to be reviewed. After the splash
screenhas beenonthe InfoCenterforseveral seconds,
themaininformationscreenwillbedisplayedonthe
InfoCenter.
The splash screen can be used to identify hour meter
reading, machine battery voltage, generator voltage
and engine status. If the fault log indicator is displayed
on the splash screen, a list of electrical faults that have
occurredisavailableonthefaultsscreen.Accessingthe
fault log is described below in Faults Screen.
The main menu and additionalinformation screens can
be accessed from the InfoCenter splash screen by
pressing and releasing the menu/back button (left but-
ton) on the display. Information on the main menu and
menu item screens is included below.
1. Battery voltage
2. Engine RPM/status
3. Hour meter
4. Fault log indicator
5. Generator voltage/statu
6. Menu/back button
7. Down button
8. Right button
Figure 16
1
5
3
6
7
8
T
247.4
n/min
STOP
13.2
52.2V
4
2