Specifications
Rev. F
Specifications
Item Description
Traction Drive Pump Variable displacement axial piston pump
with servo assisted manual displacement control (MDC)
Main relief pressure 5000 +
250 psi (344.8 + 7.2 bar)
Charge relief pressure (Pump S/N below A--96--01--XXXXX) 230 +
10 psi (15.9 + .7 bar)
Charge relief pressure (Pump S/N above A--96--01--XXXXX) 285 +
10 psi (15.9 + .7 bar)
Front Wheel Motor (2 used) Variable displacement axial piston motor
Mow/Transport speed, elec./hyd. solenoid actuated
PTO (Deck Drive) Pump Two section, external gear type
PTO (Deck Drive) Valve Block Toro, cartridge logic, elec./hyd. solenoid actuated
Relief pressure (3 relief valves: front deck, right deck, left deck) 3000 to 3200 psi (206.9 to 220.7 bar)
Deck Drive Motor (3 used) External gear type
Lift Control Valve 3 spool
Lift circuit relief pressure (S/N below 240000000) 1500 +
50 psi (103.4 + 3.4 bar)
Lift circuit relief pressure (S/N above 240000000) 2000 +
50 psi (137.9 + 3.4 bar)
NOTE: Lift pressure when measured at the LIFT test port is
Lift Circuit Relief Pressure + Counterbalance Pressure
Float/Traction Assist Manifold Block Toro, cartridge logic
Counterbalance pressure 400 +
25 psi (27.6 + 1.7 bar)
“Traction Plus” counterbalance pressure 600 +
25 psi (41.4 + 1.7 bar)
“Traction Plus” shift pressure 2000 +
50 psi (137.9 + 3.4 bar)
Lift/Steering Pump External gear type w/priority flow divider
Steering relief pressure 1500 +
50 psi (103.4 + 3.4 bar)
Steering Control Hydraulic power steering control unit
Hydraulic Oil Refer to Operator’s Manual for hydraulic oil recommendations
Reservoir Capacity 32 U.S. gallon (121.1 liter)
System Capacity 40 U.S. gallon (151.4 liter)
Oil Filter Screw--on cartridge type, 5 micron, 50 psi (3.4 bar) bypass
1. Hydraulic Oil Level Sight Glass
2. Reservoir Fill Cap
Figure 27
Note: When measuring lift circuit relief pressure,
counterbalance pressure, and “Traction Plus” counter-
balance pressure on machines with serial numbers
above 250000000, pressures will be approximately 125
psi (8.6 bar) higher than the specifications listed above.
Refer to the Testing section in this chapter for detailed