4
InstallingtheLiftValve
Model08705Only
Partsneededforthisprocedure:
2
StraighthydraulicttingwithO-ring
2
90°hydraulicttingwithO-ring
1
Liftvalve
1Valveplate
3
Bolt(1/4x3inches)
3
Locknut(1/4inch)
2
Bolt(#10x1-1/4inches)
2
Locknut(#10)
1
Liftlever
Procedure
1.Threadboth90°ttingsandthe2straight
hydraulicttingsintothenewliftvalveasshown
inFigure7.
Important:Donottightenthe90°ttings
atthistime.EnsurethatallO-ringsare
lubricatedandproperlypositionedonthe
ttingsbeforeinstallation.
g003663
Figure7
1.Straighttting3.Liftvalve
2.90°tting
2.Mountthevalveassembly,pivotbracket,and
valveplatetotheframewith3bolts(1/4x3
inches)and3locknuts(Figure8).Positionthe
valveplateagainstthefrontoftheframemember
whenmounting,andtorquethefastenersto10
to12N∙m(90to110in-lb).
Note:Thevalveinstallationisverysimilarto
theexistingvalvethatisalreadyinstalled.
3.Looselymountthepivotleverassemblytothe
valvespoolandtotheoffsetlinkwith2bolts
(#10x1-1/4inch)and2locknuts(Figure8).
Note:Donottightenthefastenersatthistime.
g003664
Figure8
1.Valveassembly
4.Offsetlink
2.Pivotbracket5.Pivot
3.Valveplate6.Lever
6