ServicingtheFuses
Theelectricalsystemisprotectedbyfuses.Itrequires
nomaintenance;however,ifafuseblows,checkthe
component/circuitforamalfunctionorshort.
Fusetype:
Main—F1(30A,blade-type)
ChargeCircuit—F2(25A,blade-type)
1.Removethescrewssecuringthecontrolpanel
tothemachine.
Note:Retainallfasteners.
2.Liftthecontrolpaneuptoaccessthemainwire
harnessandfuseblock(Figure52).
3.Toreplaceafuse,pulloutthefusetoremove
it(Figure52).
g014921
Figure52
1.Main(30A)2.Chargecircuit(25A)
4.Returnthecontrolpaneltoitsoriginalposition.
Note:Usethescrewsremovedpreviouslyto
securethepaneltothemachine.
DriveSystem
Maintenance
CheckingtheTirePressure
ServiceInterval:Every25hours—Checktire
pressure.
Maintaintheairpressureinthefrontandreartiresas
specied.Uneventirepressurecancauseuneven
cut.Checkthepressureatthevalvestem(Figure53).
Checkthetireswhentheyarecoldtogetthemost
accuratepressurereading.
Refertothemaximumpressuresuggestedbythetire
manufactureronthesidewallofthecasterwheeltires.
Formachineswith42-inchor50-inchdecks,inate
thereardrivewheeltiresto90kPa(13psi).
Formachineswith54-inchor60-inchdecks,inate
thefrontcastersandreardrivewheeltiresto103kPa
(15psi).
g000554
Figure53
1.Valvestem