EasyManua.ls Logo

Toro TITAN MX5480 - Fuel & Electrical System Maintenance

Toro TITAN MX5480
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FuelSystem
Maintenance
DANGER
Incertainconditions,gasolineisextremely
ammableandhighlyexplosive.Areorexplosion
fromgasolinecanburnyouandothersandcan
damageproperty.
Performanyfuelrelatedmaintenancewhenthe
engineiscold.Dothisoutdoorsinanopenarea.
Wipeupanygasolinethatspills.
Neversmokewhendraininggasoline,andstay
awayfromanopenameorwhereasparkmay
ignitethegasolinefumes.
ReplacingtheFuelFilter
ServiceInterval:Every100hours/Yearly(whichevercomes
rst)(moreoftenunderdusty,dirty
conditions).
1.Disengagethebladecontrolswitch(PTO),movethe
motioncontrolleverstotheneutrallockposition,and
settheparkingbrake.
2.Stoptheengine,removethekey,andwaitforallmoving
partstostopbeforeleavingtheoperatingposition.
3.Allowthemachinetocooldown.
4.Raisetheseatandlocatethefuelltersasshownin
Figure44.
g017723
1
2
3
4
5
Figure44
1.Fuellinefromtank
4.Fuellinetoengine
2.In-lineFuellter
5.Hoseclamp
3.Flowdirectionarrow
5.Squeezetheendsofthehoseclampstogetherandslide
themawayfromthelter(Figure45).
G008963
12
3
Figure45
1.Fuellter
3.Fuelline
2.Hoseclamp
6.Removethelterfromthefuellines.
7.Installanewlterwiththeowdirectionarrowcoming
fromthefueltankandpointingtotheengine.Move
thehoseclampsclosetothelter(
Figure44)tosecure
itinplace.