B-2 1600XPi Series UPS Installation and Operation Manual – 60616-014
Item Brief Description
Description
On LCD
U A D
Svc/
QC
F Default Remark
007 UPS Job Number Job No R R R R/W R/W “JB0123456789” JBXXXXXXXXX
JB – Job Number
XXXXXXXXX – Order Number
(Variable Size)
008 Test Person’s First and Last
Name Initial
Test Person R R R R/W R/W “TA” “FL” ; First Name initial then Last Name initial
009 UPS Test Date Test Date R R R R/W R/W “20150101” Format: YYYYMMDD
010 UPS Hardware Built Date HWare Built Date R R R R/W R/W “20150101” Format: YYYYMMDD
011 Main Firmware Built Date Main FWare BDate - - R R R Format: Mmm DD, YYYY
(Ex. Jan 04, 2015 Automatically read by compiler)
012 Main Firmware Built Time Main FWare
BTime
- - R R R Format: HH:MM:SS
(Ex. 18:45:45 Automatically read by compiler)
013 EEPROM Version Main EEPROM
Ver
R R R R R/W “UH3MEE00000” UXXYEEMMRRR
U – UPS
XX – 2 Alpha Numeric UPS Product Line (F3, H3)
Y – uC Projects (M – Main, S – Sub, D – Display)
EE – EEPROM Version
MM – Major version
RRR – Minor version
015 UPS System Name System Name R R/W R/W R/W R/W “TOSHIBA H3” Such as Plant3, Upstair...
016 UPS Attached Devices Attached Device R R/W R/W R/W R/W “None”
017 UPS Installation Date Installed Date R R/W R/W R/W R/W “20150101” Format: YYYYMMDD
018 CRC Checksum CRC Checksum R R 0
019 Functional Test Date Ftest Date R/W R/W “20150101” Format: YYYYMMDD
020 Functional Test File Ftest File R/W R/W “NO”