Do you have a question about the Toshiba Combi control and is the answer not in the manual?
Brand | Toshiba |
---|---|
Model | Combi control |
Category | Control Systems |
Language | English |
Details the status of the Power LED (on, blinking, off) indicating power and battery status.
Explains the GSM network LED states (on, blink, data call) for network connectivity.
Describes the IR LED status, indicating when transmitting by IR.
Details the function of the RESET button, including turning off the controller and clearing settings.
Explains the TEST button's use for turning the heat pump ON/OFF and confirming IR beam.
Describes how to perform a hard reset by pressing both buttons simultaneously for 3 seconds.
Ensures the SIM card can access the 2G network; 3G-only SIM cards are not compatible.
Details recommended placement on the wall to ensure efficient IR beam reflection to the heat pump sensor.
Other mounting configurations are possible as long as IR transmission to the pump works.
Notes that thick carpets and dark floors can distort the IR beam, advising use of the test function.
Explains that sending the SMS command 'ON' turns the heat pump on.
Explains that sending the SMS command 'OFF' turns the heat pump off.
Details the controllable temperature range (16-30°C) and fan speeds (AUTO, MIN, NORM, MAX).
Describes default temperature (20°C) and fan speed (NORM) when a mode is selected without specific user assignment.
Illustrates an SMS command example for cooling to 19°C with maximum fan speed.
Details Owner's capabilities: sending commands, queries, setup commands, and receiving messages.
Explains User's permissions: sending commands and queries, but not setup commands.
Describes All-level users' ability to make report queries about the controller's status.
Details two methods for initial owner number setup via SMS commands.
Specifies that owner numbers can be international or local, between 3-16 symbols.
Explains confirmation via 'VERSION' SMS and states initial permissions before/after user setup.
Describes resetting the owner number via mobile phone or by performing a hard reset.
Explains sending SMS '90' for setup reset, which deletes the owner and restarts the controller.
Details default parameters after reset, including owner status, commands, and alarm intervals.
Describes sending SMS '91xx' for User1 and '92xx' for User2, including format and deletion codes.
Explains using SMS '93xx' to enter the owner number during user setup, with a deletion code '930'.
Details using space, comma, or semicolon to separate multiple commands within a single SMS.
Provides an example SMS with multiple commands and explains error reporting and activation of correct commands.
Recommends setting the precise manufacturer and model for efficient operation.
Explains setting only the manufacturer, noting potential issues with T8 mode and compatibility.
Describes using SMS '950' for 'All pump models', enabling generic IR commands.
Details SMS commands for adjusting 'LOW TEMPERATURE', 'NO POWER', and 'SERVICE' alarm message conditions.
Specifies the valid numeric ranges for 'LOW TEMPERATURE' (971), 'NO POWER' (972), and 'SERVICE' (973) parameters.
Explains Combi Control alarm SMS formats, meanings, and blackout/threshold values for LOW TEMPERATURE, NO POWER, and SERVICE.
Describes the 'VERSION' alarm message, which is sent after setting a new Owner or changing the Owner.
Details the 'Error command: text' SMS, sent when there's an error in the user's command.
Explains the 'Error userrights: text' SMS, sent if the user lacks permission for a command.
Defines the 'Error pump command: text' SMS, indicating operation T8 is unavailable for the specified pump.
Describes sending a 'STATUS' command for pump status requests and its response format.
Explains sending a 'VERSION' command for controller status requests and its response details.
Describes sending a 'SETUP' command for setup configuration requests and its response format.
Explains the 'Pump: ON/OFF/NO POWER' format in the STATUS report.
Explains the 'Mode: AUTO/DRY/COOL/HEAT/T8' format in the STATUS report.
Explains the 'Fan: AUTO/MIN/NORM/MAX' format in the STATUS report.
Explains the 'Temp: xxC' format in the STATUS report for pump temperature.
Explains the 'Room: xxC' format in the STATUS report for room temperature.
Explains the 'Ver: version number' format for Combi Control firmware version.
Explains the 'Pump: type, ON/OFF' format for pump status in the VERSION report.
Explains the 'Power: ON/OFF(x.xxV)' format for voltage and battery status.
Explains the 'Room: xxC' format for room temperature in Celsius degrees.
Explains the 'GSM: sq, cell' format for GSM signal strength and network information.
Explains the 'Life: mm.dd' format for controller run time in months and days.
Explains the 'Owner: number' format for the owner mobile phone number.
Explains 'Owner: number / All' and 'Users: number1, number2 / All' formats.
Explains the 'Pump: pump manufacturer's name' format for chosen pump.
Explains the 'Ring: x,x1,x2' format for ring codes of Owner, User1, User2.
Explains 'Param: x1,x2,x3' for low temperature, no power, and service parameters.
Lists SMS commands 'ON' and 'OFF' for controlling the heat pump's power state.
Details SMS commands '90' for setup reset/restart and '93' for first-time owner number entry.