e-STUDIO2500c/3500c/3510c
(1) Enter setting mode [08]. Set "2" for code [9059].
During automatic calibration, the paper type can be selected and image quality control will be
automatically performed.
Value for 08-9059
Image quality control operation during the
automatic calibration
0 OFF (default)
1 ON (with paper selection disabled)
2 ON (with paper selection enabled)
After setting the value, use the next procedure.
(2) Perform automatic calibration to correct variations in image density.
* [ADMIN] is selected from among the [CALIBRATION DISPLAY LEVEL] options by default. In other
words, an administrator is authorized to operate the automatic calibration. But the [USER] option can also
be selected to allow the user to operate it. Refer to the User Functions Guide for further information
regarding how to select the [CALIBRATION DISPLAY LEVEL] option.
* Use steps (a) through (l) to perform the automatic calibration.
(a) Press the [USER FUNCTIONS] button on the Control Panel to enter the "User Functions" menu.
(b) Press the [ADMIN] button.
(c) Enter an administrator password of 6 to 10 digits. Press the [ENTER] button.
(d) Press the [GENERAL] button.
(e) Press the [CALIBRATION] button.
(f) Press the [PRINT] button.
(g) Press the button for the paper type to be corrected.
* After the paper type is selected, image quality control is automatically performed.
(h) Load A4/LT-sized paper selected at step (g).
(i) Press the [CALIBRATION] button to print out the test chart.
(j) Place the printed test chart on the original glass.
(k) Press the [START] button to perform calibration. When the calibration comes to an end, the message
"Scanning and calibrating" will disappear.
(l) The message "Is a result made to reflect?" will appear. Press the [YES] button.
Precautions after the completion of the adjustment
When image quality control is automatically performed during automatic calibration, the processing time will
increase by approximately 30 seconds, when compared to before when the automatic image quality control
option is selected.
PCL6 PS3 Mac