EasyManua.ls Logo

Toshiba E-STUDIO 3500C - Page 26

Toshiba E-STUDIO 3500C
232 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO2500c/3500c/3510c
To Have Uniform Variations in the Image Quality after Return from the Auto Power Save Mode:
Set the value for code 08-571 within a range of "1" to "3" to shorten the operating condition period when
image quality control is performed after the MFP is returned from the auto power save mode (time when no
MFP operations are being performed and when the MFP is left for image quality control). Image quality
control can now be easily performed.
* This adjustment will improve the image quality, but only if the sleep mode / auto shut off mode have been
disabled ("20" is set for code 08-206). Remember that there will be no positive affect on the image quality,
if the sleep mode / auto shut off mode have been enabled.
Value for
08-571
Time when the MFP is being left for image quality control
1 to 3 Performed before the MFP resumes operations after being left for 1 to 3 hour or more.
4
Performed before the MFP resumes operations after being left for 4 hours or more.
(default)
After setting the value for code 08-571, forcibly perform image quality control, as follows:
Enter adjustment mode [05]. Select code [396]. Press the [START] button.
A large number of sheets are printed (hundreds of copies or more per day) and the image
quality needs to be constantly maintained:
Set the value for code 08-572 within a range of "1" to "9" (Value × 100 sheets) to reduce the accumulated
number of printed sheets. It will determine the interval until the next image quality control is performed.
* After a copy or print job is completed, if the accumulated number of printed sheets exceeds the specified
value, image quality control will be performed.
Value for 08-572
Accumulated number of printed sheets before image quality control is performed
1 to 9 100 to 900 sheets
10 1,000 sheets (default)
After setting the value for code 08-572, forcibly perform image quality control, as follows:
Enter adjustment mode [05]. Select code [396]. Press the [START] button.
After performing the adjustment, print and check the image quality.
If further image quality adjustments are still necessary, use the next procedure.
1. General Adjustments – Copying, Printing and e-Filing (Output from Box)
1.4

Table of Contents

Other manuals for Toshiba E-STUDIO 3500C

Related product manuals