(1) Enter adjustment mode [05]. Select code [396]. Press the [START] button.
Image quality control will be forcibly performed to correct variations in image contrast.
After exercising image quality control, use the next procedure.
(2) Perform automatic calibration to correct variations in image density.
* [ADMIN] is selected from among the [CALIBRATION DISPLAY LEVEL] options by default. In other
words, an administrator is authorized to operate automatic calibration. But the [USER] option can also be
selected to allow the user to operate it. Refer to the User Functions Guide for further information
regarding how to select the [CALIBRATION DISPLAY LEVEL] option.
* Use steps (a) through (j) to perform the automatic calibration.
(a) Press the [USER FUNCTIONS] button on the Control Panel to enter the "User Functions" menu.
(b) Press the [ADMIN] button.
(c) Enter an administrator password of 6 to 10 digits. Press the [ENTER] button.
(d) Press the [GENERAL] button.
(e) Press the [CALIBRATION] button.
(f) Press the [PRINT] button.
(g) Press the [CALIBRATION] button to print out the test chart.
(h) Place the printed test chart on the original glass.
(i) Press the [START] button to perform calibration. When the calibration comes to an end, the message
"Scanning and calibrating" will disappear.
(j) The message "Is a result made to reflect?" will appear. Press the [YES] button.
<Hint> During automatic calibration, the automatic image quality control option is also available. This
option is particularly recommended for users who frequently adjust the image quality.
Use steps (a) to (b) to perform automatic image quality control.
(a) Enter setting mode [08]. Set "1" for code [9059].
Value for 08-9059
Image quality control operation during the
automatic calibration
0 OFF (default)
1 ON (with paper selection disabled)
2 ON (with paper selection enabled)
(b) Perform automatic calibration.
* Refer to the above procedure to perform automatic calibration.
* When the [COPY] button or [PRINT] button is pressed after step (f), image quality
control will be automatically performed.
Precautions after the completion of the adjustment
• When image quality control is repeatedly performed, the color balance may slightly vary due to an error even
in the same environment.
• During automatic calibration, when the automatic image quality control option is selected (procedure (2)
<Hint>), the processing time will increase by approximately 30 seconds, when compared to before when the
automatic image quality control option is selected.