e-STUDIO2500c/3500c/3510c
(2) Check the life of the consumables (particularly the drum, developer material and fuser unit) and replace
them, if necessary.
• When replacing any consumable, use steps (a) to (c).
(a) Enter the PM support mode. Reset the counter corresponding to the replaced consumable part to "0."
* For further information regarding the PM support mode, refer to the Service Handbook.
(b) Enter adjustment mode [05]. Select code [396]. Press the [START] button.
• Image quality control will be performed and the image quality control value will be initialized.
(c) Perform automatic calibration.
* For further information regarding the procedures, refer to procedure (2) in 1.1 To Obtain a Darker
Image.
* After replacing any consumable, remember to reset the counter by making it correspond to "0." Otherwise,
it may cause a loss in MFP performance, including degradation in the image quality and a reduction in the
life of the consumables.
* While replacing any consumable, also check the slit glass in the laser optical unit, and thoroughly clean it,
if it is soiled.
1. General Adjustments – Copying, Printing and e-Filing (Output from Box)