OUTLINE OF THE MACHINE
2 - 20
S23 ADU-TRL-SNR
ADU exit sensor
Detecting the transporting paper in auto-
matic duplexing unit
* e-STUDIO230/280/232/282
(NAD/AUD/MJD/IRD/CND),
e-STUDIO233/283 (NAD/MJD/CND)
models: Standard
* e-STUDIO200L/202L (NAD/ASD/
ARD), e-STUDIO203L (NAD/ARD),
e-STUDIO230/280/232/282 (ASD/
ASU/SAD/TWD/KRD),
e-STUDIO233/283(ARD),
e-STUDIO230L (MJD),
e-STUDIO280S/232S/282S/283S
(CND) models: Option
P.2-12
"Fig. 2-
15"
P32-I31
S24 EXIT-SNR
Exit sensor
Detecting the transporting paper at the
exit section
P.2-13
"Fig. 2-
16"
P31-I101
SW1 MAIN-SW
Main switch
Turning ON/OFF of the equipment P.2-7
"Fig. 2-8"
P5-I6
SW2 COV-INTLCK-SW
Cover opening/closing interlock
switch
Controlling cutoff and supply of the AC
input for DC power supply by opening/
closing of the front cover or transfer
guide.
P.2-7
"Fig. 2-8"
P5-I108
SW3 TR-COV-SW
Transfer cover opening/closing
switch
Transfer cover opening/closing switch P.2-10
"Fig. 2-
12"
P6-I113
SW4 TNR-SW
Toner cartridge installation switch
Toner cartridge presence/absence
detection
P.2-7
"Fig. 2-8"
P6-I52
SW5 FRNT-COV-SW
Front cover opening/closing switch
Detecting opening/closing of the front
cover
P.2-7
"Fig. 2-8"
P5-I102
SW6 CST-U-SW
Upper drawer detection switch
Detecting presence/absence of the
upper drawer
P.2-9
"Fig. 2-
11"
P6-I113
SW7 CST-L-SW
Lower drawer detection switch
Detecting presence/absence of the
lower drawer
P.2-9
"Fig. 2-
11"
P6-I113
SW8 ADU-SET-SW
ADU opening/closing switch
Automatic duplexing unit opening/clos-
ing detection
* e-STUDIO230/280/232/282
(NAD/AUD/MJD/IRD/CND),
e-STUDIO233/283 (NAD/MJD/CND)
models: Standard
* e-STUDIO200L/202L (NAD/ASD/
ARD), e-STUDIO203L (NAD/ARD),
e-STUDIO230/280/232/282 (ASD/
ASU/SAD/TWD/KRD),
e-STUDIO233/283(ARD),
e-STUDIO230L (MJD),
e-STUDIO280S/232S/282S/283S
(CND) models: Option
P.2-12
"Fig. 2-
15"
P32-I43
SW9 AUG-LOCK-SW
Auger lock switch
Detecting lock of the toner recovery
auger
P.2-7
"Fig. 2-8"
P6-I113
Symbol Name Function Remarks P-I