© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ADJUSTMENT
3 - 29
3
3.4.3 Gamma balance adjustment
< e-STUDIO 202L/203L/232/233/282/283 >
The gamma balance is adjusted by adjusting the density at the Black Mode. The adjustment is per-
formed by selecting its density area from the following: low density, medium density and high density.
< Adjustment Mode (05) >
Language and screen
Item to be adjusted Remarks
Smooth
(PS)
Detail
(PS)
Smooth
(PCL)
Detail
(PCL)
596-0 597-0 598-0 599-0 Low density The larger the value is, the
density of the item to be
adjusted becomes darker.
Acceptable values:
0 to 255. (Default: 128)
596-1 597-1 598-1 599-1 Medium density
596-2 597-2 598-2 599-2 High density
10/01