Procedure when the Result is NG
When NG occurs, a screen like the one shown below is displayed on the Control Panel.
1.
Check the item(s) in red.
2.
R
efer to the Correspondence table (below) and take the corrective action.
The inspection number and item results are displayed on the Control Panel. Check the
inspection number and items displayed in red ("NG" and OK?) according to the table below.
Note: If replacement of the SYS board, Main Memory, SRAM (FRAM) and FAN etc. is
required, refer to the replacement procedure in the service manual.
Important Note:
A result of NG when using the Diagnostic tool could be caused by reasons other than a
failure of the SYS board such as wiring harness related issues or wire harness connections
to other components.