AIR TO WATER HEAT PUMP
Hydro Unit
Model name:
HWS-802XWHM3-E
HWS-802XWHT6-E
HWS-1402XWHM3-E
HWS-1402XWHT6-E
HWS-1402XWHT9-E
Owner’s Manual
Owner’s Manual
Hydro Unit 2
English
Manuel du proprietaire
Unité hydroélectrique 16
Français
Betriebsanleitung
Wassergerät 30
Deutsch
Bruksanvisning
Hydroenhet 44
Svenska
z__EE99903501_4L_Hydro_OM.book Page 1 Friday, July 31, 2009 11:37 AM

Other manuals for Toshiba HWS-1402XWHT9-E

Questions and Answers

  • H
    hannahcampbellAug 13, 2025
    Why is my Toshiba Heat Pump not heating or cooling properly?
    • J
      Jeremy FreemanAug 13, 2025
      There are several reasons why your Toshiba Heat Pump might not be heating or cooling effectively. It could be due to an incorrect setting on the remote controller. Make sure to check the remote controller operation and temperature settings. It may also be due to an incorrect function code setting. Refer to the function code table to verify the settings. Another possible cause is a disconnected backup heater, so you should inspect the backup heater and bimetal thermostat. Insufficient capacity of the heat pump itself or a defect with the temperature sensor could also be factors. Check the equipment selection and ensure the temperature sensor is installed correctly.
  • N
    Noah NovakAug 17, 2025
    Why is my Toshiba HWS-1402XWHT9-E Heat Pump not cooling or heating?
    • C
      Courtney MorganAug 17, 2025
      There might be several reasons why your Toshiba Heat Pump isn't cooling or heating the room: * Check if the scheduled operation is set, as this could be affecting the temperature. * Verify the settings on the remote controller to ensure night setback operation isn't active. * If the air conditioner is in Auto mode, the target temperature is automatically set based on the outdoor unit temperature. Note that the Auto mode can be adjusted by contacting the installation company.
  • D
    Donald LewisAug 21, 2025
    What to do if my Toshiba HWS-1402XWHT9-E remote controller displays nothing?
    • T
      Teresa PrattAug 21, 2025
      If the remote controller for your Toshiba Heat Pump isn't displaying anything, the first thing to check is the power supply wiring to ensure it's properly connected. Also, verify the DIP switch setting on the Hydro Unit board, using the function code table to confirm the setting.
  • B
    bkingAug 25, 2025
    What to do if Toshiba HWS-1402XWHT9-E Heat Pump is not supplying hot water?
    • T
      Timothy DavisAug 25, 2025
      If your Toshiba Heat Pump isn't supplying hot water, consider the following: * Ensure that the main water supply cock is open and check all valves. * Be mindful of hot water usage. If you use hot water exceeding the storage capacity, the supplied water temperature will be lower than the set temperature.
  • W
    william57Aug 28, 2025
    How to fix Toshiba HWS-1402XWHT9-E Heat Pump remote controller when nothing is displayed?
    • M
      Michael MartinezAug 28, 2025
      If nothing is displayed on the remote controller of your Toshiba Heat Pump: * Check whether power is supplied to the remote controller. * Ensure that the circuit breaker switch is turned on.
  • S
    Scott BradleySep 1, 2025
    How to stop time indication from blinking on Toshiba HWS-1402XWHT9-E?
    • S
      schwartzelizabethSep 1, 2025
      If the time indication is blinking on your Toshiba Heat Pump, set the date and time.
  • S
    Susan HolmesSep 5, 2025
    What to do if hot water leaks from the pressure relief valve of my Toshiba HWS-1402XWHT9-E Heat Pump?
    • M
      melissa77Sep 5, 2025
      If hot water is leaking from the pressure relief valve of your Toshiba Heat Pump, it could be due to excessive hydraulic pressure. Set the hydraulic pressure considering the pipe height, and replenish water until the manometer shows a value of set hydraulic pressure or more. Another cause might be an insufficient capacity of the expansion tank compared to the total water amount, in which case you should consider installing another expansion tank. A failure of the expansion tank itself could also be the reason; check the air pressure.
  • J
    John TurnerSep 9, 2025
    How to fix the error code [P01] on my Toshiba Heat Pump due to flow rate switch activation?
    • H
      Haley BennettSep 9, 2025
      If your Toshiba Heat Pump displays error code [P01] and the flow rate switch is activated, it could be due to several reasons. First, there might be air trapped in the pump; release the air completely according to the proper procedure. Low hydraulic pressure could also trigger this error; set the hydraulic pressure considering the pipe height, and replenish water until the manometer shows a value of set hydraulic pressure or more. A clogged strainer, large resistance on the hydro side, or a malfunction of the motorized 3-way valve for hot water supply could also be the cause. Clean the strainer, widen the water path to the hydro unit or adopt a bypass valve, and check the wiring and parts of the 3-way valve.

Summary

SAFETY PRECAUTIONS

INSTALLATION WARNINGS

Critical safety instructions for installing the unit, covering grounding and component usage.

OPERATION WARNINGS

Safety advice for operating the unit, including fan hazards and responding to unusual signs.

WARNINGS AT MOVEMENT AND REPAIR

Precautions regarding moving or repairing the unit, emphasizing qualified personnel and high voltage risks.

NAMES AND FUNCTIONS OF PARTS

Buttons

Describes the function and purpose of each button on the remote controller and unit.

Meaning of Indication

Explains the various indicators and symbols displayed on the remote controller for heating and hot water sides.

HOW TO USE FUNCTIONS

Timer setting

Step-by-step guide to setting the current time, day, and weekly operation schedules.

Setting temperature

Instructions on how to adjust the desired temperature for heating, cooling, and hot water zones.

Performing Auto mode operation

Details on how the unit automatically adjusts temperature based on outside conditions and how to correct settings.

Night setback

How to configure reduced heating operation during nighttime to save energy.

Frost protection

Explanation of the function to prevent pipe freezing during long periods of absence.

Hot water boost

How to temporarily prioritize hot water supply with a higher target temperature.

Anti bacteria

How to activate the function for periodic hot water tank sterilization to prevent bacterial growth.

Schedule timer

Guide to programming daily operations in up to eight steps for heating and hot water.

USER MAINTENANCE

3 minutes protection function

Explains the delay preventing immediate restart after power interruption or switch-off.

Power failure

Describes how the unit behaves during a power outage and how to restart.

Heating characteristics

Details on defrosting operation and heating capacity, including advice for low temperatures.

Attention to snowfall and freeze on the outdoor unit

Precautions for snowy or cold conditions affecting the outdoor unit's performance.

Air to water heat pump operating conditions

Recommended outdoor and room temperature ranges for optimal cooling, heating, and hot water operation.

AIR TO WATER HEAT PUMP OPERATIONS AND PERFORMANCE

General Specifications

Technical details including capacity, input, COP, EER, power supply, and dimensions for various models.

TROUBLESHOOTING