AIR TO WATER HEAT PUMP
Hydro Unit
Model name:
HWS-803XWHM3-E
HWS-803XWHT6-E
HWS-803XWHD6-E
HWS-803XWHT9-E
HWS-1403XWHM3-E
HWS-1403XWHT6-E
HWS-1403XWHD6-E
HWS-1403XWHT9-E
Owner’s Manual
Owner’s Manual
Hydro Unit 1
English
Manuel du propriétaire
Unité hydroélectrique 15
Français
Bedienungsanleitung
Hydrogerät 29
Deutsch
Bruksanvisning
Hydroenhet 43
Svenska
+00EF99904001_01EN.book Page 1 Monday, June 28, 2010 6:17 PM

Other manuals for Toshiba HWS-1403XWHM3-E

Questions and Answers

  • T
    Toni VazquezAug 20, 2025
    Why is my Toshiba HWS-1403XWHM3-E not heating or cooling properly?
    • S
      Stephanie RossAug 20, 2025
      There are several reasons why your Toshiba Heat Pump might not be heating or cooling effectively. It could be due to an incorrect remote controller setting, so check your operation and temperature settings. An incorrect function code setting could also be the cause; verify the function code setting using the function code table. Other potential issues include a disconnected backup heater (check the heater and bimetal thermostat), insufficient capacity (check the equipment selection), or a sensor defect (ensure the temperature sensor is correctly positioned).
  • C
    Courtney MillerAug 21, 2025
    Why is my Toshiba HWS-1403XWHM3-E Heat Pump not cooling or heating?
    • K
      Kayla FordAug 22, 2025
      Your Toshiba Heat Pump might not be cooling or heating because a scheduled operation is set. Please check whether scheduled operation is set. Also, check the remote controller to see if night setback operation is enabled. If the air to water heat pump is operating in Auto mode, the target value is set automatically according to the outdoor unit temperature. Note that the Auto mode can be adjusted, but you should contact the installation company for assistance.
  • S
    Steven SnowAug 25, 2025
    Why is nothing displayed on my Toshiba Heat Pump remote controller?
    • J
      jtaylorAug 25, 2025
      If nothing is displayed on your Toshiba Heat Pump remote controller, the issue could be that power is not being supplied. Check the power supply wiring. Alternatively, there might be an incorrect setting; check the DIP switch setting on the Hydro Unit board and compare it with the function code table.
  • T
    Tracy WallsAug 26, 2025
    What causes a Toshiba HWS-1403XWHM3-E Heat Pump E03 communication error?
    • T
      Thomas WadeAug 27, 2025
      If you're experiencing a regular communication error E03 between the hydro unit and the remote controller of your Toshiba Heat Pump, check the remote control connection. Also, check the remote control for any defects.
  • M
    mlindseyAug 28, 2025
    What to do if my Toshiba HWS-1403XWHM3-E Heat Pump is not supplying hot water?
    • G
      gmuellerAug 28, 2025
      If your Toshiba Heat Pump isn't supplying hot water, first check if the main water supply cock is closed and ensure the valves are open. Also, consider whether you are using too much hot water; if you use hot water exceeding the storage capacity, water at a temperature lower than the set hot water temperature will be supplied.
  • J
    Jessica HamiltonAug 30, 2025
    How to fix a Toshiba HWS-1403XWHM3-E Heat Pump remote controller with no display?
    • J
      James LewisAug 30, 2025
      If nothing is displayed on your Toshiba Heat Pump remote controller, check whether power is supplied to the remote. Ensure that the circuit breaker switch is turned on.
  • B
    Barbara HouseSep 1, 2025
    How to fix a Toshiba HWS-1403XWHM3-E remote controller when nothing is displayed?
    • S
      Sandra IngramSep 1, 2025
      If nothing is displayed on your Toshiba Heat Pump remote controller, there are a couple of things to check. First, ensure that power is being supplied to the remote controller by checking the power supply wiring. Also, verify the DIP switch setting on the Hydro Unit board and compare it with the function code table to ensure it is set correctly.
  • C
    Christine RodriguezSep 3, 2025
    How to troubleshoot regular communication errors between the hydro unit and remote controller of my Toshiba HWS-1403XWHM3-E?
    • S
      stoneoscarSep 3, 2025
      To troubleshoot communication errors between the hydro unit and the remote controller, check the remote control connection. Also, there may be a defect in the remote control.
  • N
    Nicholas JonesSep 5, 2025
    What causes regular communication errors between the hydro unit and outdoor unit of a Toshiba Heat Pump?
    • H
      Hunter HarmonSep 5, 2025
      To address communication errors between the hydro unit and outdoor unit, check the serial circuit. Also, look for miswiring of the crossover between the water heat exchanger and the outdoor unit.
  • A
    Anthony JohnsonSep 7, 2025
    What to do if hot water leaks from the Toshiba HWS-1403XWHM3-E pressure relief valve?
    • H
      Hayden NielsenSep 7, 2025
      If hot water is leaking from the pressure relief valve of your Toshiba Heat Pump, it could be due to excessive hydraulic pressure. Set the hydraulic pressure considering the pipe height, and replenish water until the manometer shows a value of set hydraulic pressure or more. Another cause might be insufficient capacity of the expansion tank; check its capacity compared to the total water amount, and install another expansion tank if needed. Finally, the expansion tank might have failed, so check the air pressure.

Summary

Safety Precautions and Warnings

Installation Safety

Covers warnings and cautions related to the unit's installation process.

Operation Safety

Covers warnings and cautions related to the unit's operation.

Movement and Repair Safety

Covers warnings regarding moving or repairing the unit.

Power Connection Safety

Instructions for safely connecting the appliance to the main power supply.

Unit Components and Indicators

Control Buttons

Details the purpose and function of each button on the remote control.

System Indicators

Explains the various indicators and symbols displayed on the unit.

Operating the Heat Pump System

Timer and Schedule Settings

Guides on setting the current time, day, and weekly schedules.

Heating and Cooling Operations

Instructions for performing heating or cooling operations.

Automatic Temperature Control

How to use the automatic temperature adjustment feature.

Hot Water Supply Operation

Instructions for operating the hot water supply function.

Advanced Functions and Settings

Frost Protection

Explains frost protection operation for preventing pipe freezing during absence.

Night Setback Operation

Details the night setback function for saving heating during sleep hours.

Hot Water Boost

Explains the hot water boost function for temporary priority supply.

Anti-Bacteria Function

Describes the anti-bacteria operation for the hot water tank.

Schedule Timer Setup

Guides on setting up daily and weekly operational schedules.

Maintenance and Performance

User Maintenance Schedule

Recommends periodic maintenance and contacting the installer.

Operating Conditions

Details optimal temperature ranges for cooling, heating, and hot water.

General Specifications

Single Phase Models

Technical specifications for single-phase outdoor units.

Three Phase Models

Technical specifications for three-phase outdoor units.

Hydro Unit Specifications

Technical details for various Hydro Unit models.

Troubleshooting Common Issues

Remote Controller Issues

Checks for issues like no display or blinking time on the remote.

Heating;Cooling Problems

Troubleshooting steps for rooms not being cooled or heated properly.

Hot Water Supply Issues

Addresses problems related to insufficient or no hot water supply.