– 5 –
Hydro Unit
Installation Manual
Under no circumstances must the power cable be extended.
Poor connections, where the cables are joined, may give rise to
smoking and/or fire.
Ensure refrigeration system remains sealed to external gases and
air.
Should air or other gases contaminate the refrigeration circuit,
high system pressures could result in burst pipes and injuries.
Do not modify or bypass any of safety guards or switches in this
system.
After unpacking the Outdoor Unit, examine the unit carefully for
any possible damage.
Do not install in any place that might increase the vibration of the
unit.
To avoid personal injury (with sharp edges), be careful when
handling the Hydro Unit.
Due to the heavy weight of the unit, please ensure appropriate
levels of care, is taken when moving and positioning the unit into
its final location.
Perform installation work properly in accordance with the
installation manual.
Inappropriate installation may result in water leaks, electric shock
or fire.
Tighten all flare nuts with a torque wrench in the specified manner.
Excessive tightening of the flare nut may result in cracking of the
pipe work or flare nut which may result in a refrigerant leakage.
Wear heavy duty gloves during installation work to avoid injury.
Install the Outdoor Unit securely in a location where the base can
sustain the weight adequately.
In enclosed areas, if the refrigerant leaks during installation vacate
and ventilate immediately.
After installation is complete ensure and confirm that refrigerant
does not leak.
If refrigerant leaks into a room and flows near a fire source noxious
gas may be generated.
Do not block any drain hoses. Hoses may come off and electric
shocks may occur.
Install in room with water drain.
This appliance is intended to be permanently connected to the
water mains and not connected by a hose set.
The maximum inlet water pressure for DHW is 0.6 MPa.
The maximum inlet water pressure for space heating is 0.25 MPa.
The minimum inlet water pressure for space heating is 0.05 MPa.