Installation Manual 1
English
AIR CONDITIONER (MULTI TYPE)
Installation Manual
For commercial use
Outdoor Unit
Model name:
MCY-MAP0401TP Series
MCY-MAP0501TP Series
MCY-MAP0601TP Series
2FAN_IM_DB04905901-00.book Page 1 Friday, October 24, 2014 3:19 PM
1121701001
Question and Answer IconNeed help?

Do you have a question about the Toshiba MCY-MAP0401TP Series and is the answer not in the manual?

Toshiba MCY-MAP0401TP Series Specifications

General IconGeneral
RefrigerantR410A
Cooling Capacity4.0 kW
Heating Capacity4.5 kW
Outdoor Unit Weight32 kg
SeriesMCY-MAP0401TP
Power Supply220-240V, 50Hz
Outdoor Unit Noise Level50 dB

Summary

1 Precautions for Safety

General Safety Warnings

General safety warnings and precautions for installation and operation.

2 Accessory Parts

3 New Refrigerant Air Conditioner Installation

Required Tools and Handling Cautions

Lists required tools and essential cautions for installing new refrigerant AC.

4 Installation Conditions

Pre-installation Checks

Covers airtight test, air purge, electrical wiring, and earthing requirements.

Test Run Preparation

Instructions for preparing and conducting a test run.

Installation Location Guidelines

Specifies approved and prohibited locations for outdoor unit installation.

Necessary Installation Space

Obstacle Clearances

Required clearances around the unit based on obstacles.

Outdoor Unit Base Installation

Securing the Base

Instructions for firmly fixing the base with anchor bolts.

5 Refrigerant Piping

Leading Out Pipes and Optional Parts

How to lead out pipes and optional parts required for installation.

Refrigerant Piping Connection

Pipe Connection Method and Requirements

Details on pipe connection, flaring, and brazing requirements.

Pipe Material and Size Selection

R410A Pipe Specifications

Guidelines for selecting pipe materials and sizes for R410A systems.

Allowable Refrigerant Piping Lengths

Length/Height Differences for Multiple Units

Specifies maximum allowable lengths and height differences for piping.

Installation Cautions and Airtight Test

General Installation Cautions

Important cautions to follow during the installation process.

Airtight Test Procedure

Steps for conducting an airtight test to detect leaks.

Air Purge and Refrigerant Addition

Air Purge Method

Procedure for purging air from the refrigerant system.

Additional Refrigerant Calculation

How to calculate and add refrigerant for piping lengths.

Refrigerant Charging and Pipe Finishing

Refrigerant Charging and Pipe Insulation

Details on charging refrigerant and insulating pipes.

Pipe Finishing and Holding Brackets

Instructions for finishing pipe connections and using pipe holding brackets.

6 Electric Wiring

Power Wiring Selection

Details on selecting appropriate power wiring and circuit breakers.

Communication Wiring Specifications

Design and summary of communication wiring for the system.

Group Control and Wire Connections

Group Control Setup

How to set up group control for multiple indoor units.

Power and Communication Wire Connections

Procedures for connecting power and communication wires.

Power Supply Wire Connection

Terminal Screw Tightening

Guidance on connecting power supply wires and screw tightening torque.

7 Address Setting

Communication Wire Connection

How to connect communication wires to the terminal board.

Automatic Address Setting Procedures

Steps for automatic address setting for single and multi-line systems.

Manual Address Setting

Setting Addresses via Remote Controller

Instructions for manually setting addresses using the remote controller.

Confirming Indoor Unit Addresses

Verifying Unit Numbers and Positions

How to check indoor unit addresses and their physical positions.

Changing Indoor Unit Address

Modifying Addresses via Remote Controller

Guide to changing indoor unit addresses using a wired remote controller.

Resetting Indoor Unit Addresses

Address Reset Methods

Procedures for resetting addresses to factory defaults.

8 Test Run

Pre-Test Run Checks

Essential checks before performing a test run.

Test Run Methods

Procedures for executing test runs using remote controllers or PC boards.

Test Run with Outdoor Unit Interface

Individual Unit Test Run

How to perform an individual test run for each indoor unit.

Collective Test Run

How to perform a collective test run for all connected indoor units.

9 Troubleshooting

7-Segment Display Codes

Interpreting 7-segment display codes for troubleshooting.

Check Code Directory

A list of check codes and their corresponding error names.

Refrigerant Leakage Warnings

Concentration Limit Checks

Guidelines on refrigerant concentration limits and necessary measures.

Important Notes on Room Volume

Notes regarding minimum room volume requirements for safety.