AIR CONDITIONER (MULTI TYPE)
SERVICE MANUAL
Indoor unit
<4-way cassette type>
MMU-UP0091HP-E(TR)
MMU-UP0121HP-E(TR)
MMU-UP0151HP-E(TR)
MMU-UP0181HP-E(TR)
MMU-UP0241HP-E(TR)
MMU-UP0271HP-E(TR)
MMU-UP0301HP-E(TR)
MMU-UP0361HP-E(TR)
MMU-UP0481HP-E(TR)
MMU-UP0561HP-E(TR)
<Ceiling type>
MMC-UP0151HP-E(TR)
MMC-UP0181HP-E(TR)
MMC-UP0241HP-E(TR)
MMC-UP0271HP-E(TR)
MMC-UP0361HP-E(TR)
MMC-UP0481HP-E(TR)
MMC-UP0561HP-E(TR)
<Concealed Duct Standard type>
MMD-UP0051BHP-E
MMD-UP0071BHP-E(TR)
MMD-UP0091BHP-E(TR)
MMD-UP0121BHP-E(TR)
MMD-UP0151BHP-E(TR)
MMD-UP0181BHP-E(TR)
MMD-UP0241BHP-E(TR)
MMD-UP0271BHP-E(TR)
MMD-UP0301BHP-E(TR)
MMD-UP0361BHP-E(TR)
MMD-UP0481BHP-E(TR)
MMD-UP0561BHP-E(TR)
<Concealed Duct High Static Pressure type>
MMD-UP0181HP-E(TR)
MMD-UP0241HP-E(TR)
MMD-UP0271HP-E(TR)
MMD-UP0361HP-E(TR)
MMD-UP0481HP-E(TR)
MMD-UP0561HP-E(TR)
MMD-UP0721HP-E(TR)
MMD-UP0961HP-E(TR)
<Concealed Duct High Static Pressure
fresh air intake type>
MMD-UP0481HFP-E(TR)
MMD-UP0721HFP-E(TR)
MMD-UP0961HFP-E(TR)
MMD-UP1121HFP-E(TR)
MMD-UP1281HFP-E(TR)
<Console type>
MML-UP0071NHP-E(TR)
MML-UP0091NHP-E(TR)
MML-UP0121NHP-E(TR)
MML-UP0151NHP-E(TR)
MML-UP0181NHP-E(TR)
<High wall type>
MMK-UP0031HP-E(TR)
MMK-UP0051HP-E(TR)
MMK-UP0071HP-E(TR)
MMK-UP0091HP-E(TR)
MMK-UP0121HP-E(TR)
MMK-UP0151HP-E(TR)
MMK-UP0181HP-E(TR)
MMK-UP0241HP-E(TR)
MMK-UP0031HPL-E(TR)
MMK-UP0051HPL-E(TR)
MMK-UP0071HPL-E(TR)
MMK-UP0091HPL-E(TR)
MMK-UP0121HPL-E(TR)
MMK-UP0151HPL-E(TR)
MMK-UP0181HPL-E(TR)
MMK-UP0241HPL-E(TR)
FILE NO. SVM-20095
January, 2021

Table of Contents

Other manuals for Toshiba MMD-UP0481BHP-E

Questions and Answers:

Toshiba MMD-UP0481BHP-E Specifications

General IconGeneral
CategoryAir Conditioner
Cooling Capacity4.8 kW
Heating Capacity5.2 kW
Power Supply220-240 V, 50 Hz
RefrigerantR410A
Indoor Unit Noise Level45 dB

Summary

1. SPECIFICATIONS

1-1. 4-way cassette type

Detailed specifications for the 4-way cassette type indoor units, including capacity, electrical characteristics, dimensions, and sound levels.

1-2. Ceiling type

Detailed specifications for ceiling type indoor units, covering capacity, electrical characteristics, dimensions, and sound levels.

1-3. Concealed Duct Standard type

Specifications for concealed duct standard type indoor units, including capacity, electrical data, dimensions, and sound power.

1-4. Concealed Duct High Static Pressure type

Specifications for concealed duct high static pressure type indoor units, detailing capacity, electrical characteristics, dimensions, and sound.

1-5. Concealed Duct High Static Pressure fresh air intake type

Specifications for concealed duct high static pressure fresh air intake units, covering capacity, electrical data, dimensions, and sound.

1-6. Console type

Specifications for console type indoor units, including capacity, electrical details, dimensions, and sound pressure levels.

1-7. High wall type

Specifications for high wall type indoor units, detailing capacity, electrical characteristics, dimensions, and sound levels.

2. CONSTRUCTION VIEWS (EXTERNAL VIEWS)

2-1. 4-way cassette type

External views and dimensions for 4-way cassette type indoor units, illustrating installation and service clearances.

2-2. Ceiling type

External views and dimensions for ceiling type indoor units, showing installation requirements and component layout.

2-3. Concealed Duct Standard type

External views and dimensions for concealed duct standard type units, detailing installation space and unit dimensions.

2-4. Concealed Duct High Static Pressure type

External views and dimensions for concealed duct high static pressure units, including installation and service space.

2-5. Concealed Duct High Static Pressure fresh air intake type

External views and dimensions for concealed duct high static pressure fresh air intake units, covering installation and service requirements.

2-6. Console type

External views and dimensions for console type indoor units, showing installation space and mounting details.

2-7. High wall type

External views and dimensions for high wall type indoor units, illustrating installation procedures and space requirements.

3. WIRING DIAGRAMS

3-1. 4-way cassette type

Wiring diagram for the 4-way cassette type indoor units, illustrating electrical connections and component layout.

3-2. Ceiling type

Wiring diagram for ceiling type indoor units, showing electrical connections and component layout.

3-3. Concealed Duct Standard type

Wiring diagram for concealed duct standard type indoor units, detailing electrical connections and component layout.

3-4. Concealed Duct High Static Pressure type

Wiring diagram for concealed duct high static pressure type units, showing electrical connections and component layout.

3-5. Concealed Duct High Static Pressure fresh air intake type

Wiring diagram for concealed duct high static pressure fresh air intake units, detailing electrical connections.

3-6. Console type

Wiring diagram for console type indoor units, illustrating electrical connections and component layout.

3-7. High wall type

Wiring diagram for high wall type indoor units, showing electrical connections and component layout.

4. PARTS RATING

5. REFRIGERANT CYCLE DIAGRAM

6. CONTROL OUTLINE

7. COMMUNICATION TYPE, MODEL NAMES AND THE MAXIMUM NUMBER OF CONNECTABLE UNITS

8. APPLIED CONTROL AND FUNCTIONS (INCLUDING CIRCUIT CONFIGURATION)

8-1. Indoor controller block diagram (MCC-1643)

Block diagram for indoor controller MCC-1643, detailing connections for wired remote controllers.

8-2. Indoor controller block diagram (MCC-1720)

Block diagram for indoor controller MCC-1720, illustrating connections for wired and wireless remote controllers.

8-3. Indoor controller block diagram (MCC-1696)

Block diagram for indoor controller MCC-1696, showing connections for wired and wireless remote controllers.

8-4. Indoor Print Circuit Board

Identification of components and connectors on the indoor P.C. boards for MCC-1643, MCC-1720, and MCC-1696.

8-5. Test run of indoor unit

Procedure for performing cooling/heating test runs on indoor units using wired and wireless remote controllers.

8-6. Method to set indoor unit function DN code

Instructions for setting indoor unit functions and DN codes using wired remote controllers.

8-7. Applied control of indoor unit

Details on applying control systems using remote location ON/OFF control boxes for indoor units.

9. TROUBLESHOOTING

9-1. Overview

General overview of troubleshooting, including applicable models, required tools, and normal behaviors.

9-2. Troubleshooting method

Methodology for identifying trouble sites using check codes displayed on remote controllers and outdoor units.

9-3. Troubleshooting based on information displayed on remote controller

Procedure for troubleshooting issues by interpreting information displayed on the remote controller.

9-4. Check Codes Displayed on Remote Controller and SMMS series Outdoor Unit (7-Segment Display on I/F Board) and Locations to Be Checked

Detailed list of check codes, their locations, descriptions, system status, and check items for diagnosis.

9-5. Diagnostic Procedure for Each Check Code (Indoor Unit)

Diagnostic flowcharts for various check codes related to indoor units, guiding troubleshooting steps.

9-6. Sensor characteristics

Graphs and tables showing the resistance characteristics of indoor unit sensors (TA, TC1, TC2, TCJ) versus temperature.

9-7. Maintenance list

Recommended maintenance schedule and checks for indoor and outdoor units to ensure effective operation.

10. P.C. BOARD EXCHANGE PROCEDURES

10-1. Replacement of indoor P.C. boards

Procedures for replacing indoor unit P.C. boards, including EEPROM data handling and setting verification.

11. DETACHMENTS

11-1. 4-way cassette type

Procedures for detaching and attaching parts for 4-way cassette type indoor units, including suction grille and electric parts cover.

11-2. Ceiling type

Procedures for detaching and attaching parts for ceiling type indoor units, such as air intake grille and electric parts box.

11-3. Concealed Duct Standard type

Procedures for detaching and attaching parts for concealed duct standard type units, including air filters and suction panels.

11-4. Concealed Duct High Static Pressure type

Procedures for detaching and attaching parts for concealed duct high static pressure units, such as electric parts box and control board.

11-5. Concealed Duct High Static Pressure fresh air intake type

Procedures for detaching and attaching parts for concealed duct high static pressure fresh air intake units.

11-6. Console type

Procedures for detaching and attaching parts for console type indoor units, including front panel and electric parts box assembly.

11-7. High wall type

Procedures for detaching and attaching parts for high wall type indoor units, such as air inlet grille and air filters.

12. EXPLODED VIEWS AND PARTS LIST

12-1. 4-way cassette type

Exploded view and parts list for MMU-UP0091HP-E(TR) to MMU-UP0181HP-E(TR) models.

12-2. Ceiling type

Exploded view and parts list for MMC-UP0151HP-E(TR) and MMC-UP0181HP-E(TR) models.

12-3. Concealed Duct Standard type

Exploded view and parts list for MMD-UP0051BHP-E to MMD-UP0121BHP-E(TR) models.

12-4. Concealed Duct High Static Pressure type

Exploded view and parts list for MMD-UP0181HP-E(TR) to MMD-UP0271HP-E(TR) models.

12-5. Concealed Duct High Static Pressure fresh air intake type

Exploded view and parts list for MMD-UP0481HFP-E(TR) to MMD-UP0561HP-E(TR) models.

12-6. Console type

Exploded view and parts list for MML-UP0071NHP-E(TR) to MML-UP0181NHP-E(TR) models.

12-7. High wall type

Exploded view and parts list for MMK-UP0031HP-E(TR) to MMK-UP0121HP-E(TR) models.