AIR CONDITIONER (MULTI TYPE)
SERVICE MANUAL
FILE No. A10-033-1
This service manual provides relevant explanations about new indoor unit (4 series). Please refer to
the following service manuals for each indoor units.
Indoor unit
<1-way Cassette Type (YH, SH)>
MMU-AP0074YH-E(-TR)
MMU-AP0094YH-E(-TR)
MMU-AP0124YH-E(-TR)
MMU-AP0154SH-E(-TR)
MMU-AP0184SH-E(-TR)
MMU-AP0244SH-E(-TR)
<Concealed Du ct Hig h Static
Pressu re Type>
MMD-AP0184H-E(-TR)
MMD-AP0244H-E(-TR)
MMD-AP0274H-E(-TR)
MMD-AP0364H-E(-TR)
MMD-AP0484H-E(-TR)
MMD-AP0724H-E(-TR)
MMD-AP0964H-E(-TR)
<Floor Standing Concealed Type>
MML-AP0074BH-E(-TR)
MML-AP0094BH-E(-TR)
MML-AP0124BH-E(-TR)
MML-AP0154BH-E(-TR)
MML-AP0184BH-E(-TR)
MML-AP0244BH-E(-TR)
<Comp act 4-way Cas sette Ty pe>
MMU-AP0074MH-E(-TR)
MMU-AP0094MH-E(-TR)
MMU-AP0124MH-E(-TR)
MMU-AP0154MH-E(-TR)
MMU-AP0184MH-E(-TR)
<Ceiling Type>
MMC-AP0154H-E(-TR)
MMC-AP0184H-E(-TR)
MMC-AP0244H-E(-TR)
MMC-AP0274H-E(-TR)
MMC-AP0364H-E(-TR)
MMC-AP0484H-E(-TR)
<Floor Standing Cabinet Type>
MML-AP0074H-E(-TR)
MML-AP0094H-E(-TR)
MML-AP0124H-E(-TR)
MML-AP0154H-E(-TR)
MML-AP0184H-E(-TR)
MML-AP0244H-E(-TR)
<Slim Du ct Type>
MMD-AP0074SPH-E(-TR)
MMD-AP0094SPH-E(-TR)
MMD-AP0124SPH-E(-TR)
MMD-AP0154SPH-E(-TR)
MMD-AP0184SPH-E(-TR)
<Floor Stan ding Type>
MMF-AP0154H-E(-TR)
MMF-AP0184H-E(-TR)
MMF-AP0244H-E(-TR)
MMF-AP0274H-E(-TR)
MMF-AP0364H-E(-TR)
MMF-AP0484H-E(-TR)
MMF-AP0564H-E(-TR)
<Concealed Duct Standard Type>
MMD-AP0074BH-E(-TR),
MMD-AP0124BH-E(-TR),
MMD-AP0154BH-E(-TR),
MMD-AP0184BH-E(-TR),
MMD-AP0274BH-E(-TR),
MMD-AP0364BH-E(-TR),
MMD-AP0564BH-E(-TR)
PRINTED IN JAPAN,
Jul, 2012, ToMo
Indoor unit
Model name:
4-way Cassette Type (MMU-AP
∗∗∗
∗∗∗
∗∗∗
∗∗∗
∗∗∗
2H) A08-004
2-way Cassette Type (2 series) (MMU-AP 2WH) A10-007
Fresh Air Intake Indoor Unit Type (MMD-AP 1HFE) A06-016
High-wall Type (2 series) (MMK-AP 2H) SVM-05052-1
High-wall Type (3 series) (MMK-AP 3H) SVM-09059
Other indoor units (1 series) A03-009, A03-010, A05-006, A05-007, A06-002
MMD-AP0094BH-E(-TR),
MMD-AP0244BH-E(-TR),
MMD-AP0304BH-E(-TR),
MMD-AP0484BH-E(-TR),
REVISION 1 : Mar.2012
Re-edit version.( file volume down)
Contents have NOT been changed.

Table of Contents

Other manuals for Toshiba MMU-AP0184MH-E

Questions and Answers:

Toshiba MMU-AP0184MH-E Specifications

General IconGeneral
BrandToshiba
ModelMMU-AP0184MH-E
CategoryAir Conditioner
LanguageEnglish

Summary

Wiring Diagrams

1-1. Compact 4-way cassette type

Wiring diagram for compact 4-way cassette indoor units.

1-2. 1-way cassette type (compact type YH)

Wiring diagram for 1-way cassette (YH) indoor units.

1-3. 1-way cassette type (SH)

Wiring diagram for 1-way cassette (SH) indoor units.

1-4. Concealed duct standard type

Wiring diagram for concealed duct standard indoor units.

1-5. Concealed duct high static pressure type

Wiring diagram for concealed duct high static pressure indoor units.

1-6. Slim duct type

Wiring diagram for slim duct indoor units.

1-7. Ceiling type

Wiring diagram for ceiling type indoor units.

1-8. Floor standing cabinet type

Wiring diagram for floor standing cabinet indoor units.

1-9. Floor standing concealed type

Wiring diagram for floor standing concealed indoor units.

1-10. Floor standing type

Wiring diagram for floor standing indoor units.

Parts Rating

2-1. Indoor unit

Parts rating for indoor units, covering various types.

Control Outline

Indoor unit

Control specifications and operational outlines for indoor units.

Applied Control and Functions (Including Circuit Configuration)

5-1. Indoor controller block diagram

Block diagrams illustrating indoor controller configurations with remote controllers.

5-2. Indoor printed circuit board

Detailed diagrams of indoor unit printed circuit boards (MCC-1402, MCC-1403).

5-3. Optional connector specifications of indoor P.C. board

Specifications for optional connectors on indoor unit P.C. boards.

5-4. Test operation of indoor unit

Procedure for checking indoor unit operation independently of external controls.

5-5. Method to set indoor unit function DN code

Steps to set indoor unit functions using DN codes via a wired remote controller.

5-6. Applied control of indoor unit

Details on applied control systems using remote controller interfaces (TCB-IFCB4E2).

Troubleshooting

6-1. Overview

General information, required tools, and common behaviors for troubleshooting.

6-2. Troubleshooting method

Procedure for identifying faults using check codes displayed on controllers and interface boards.

6-3. Troubleshooting based on information displayed on remote controller

Method for troubleshooting using main remote controller (RBC-AMT32E) displays and error history.

6-4. Check codes displayed on remote controller and SMMS outdoor unit (7-segment display on I/F board) and locations to be checked

Detailed fault codes and corresponding check items for remote controllers and outdoor units.

6-5. Sensor characteristics

Temperature sensor characteristics (TA, TC1, TC2, TCJ) with resistance values.

P.C. Board Exchange Procedures

7-1. Replacement of indoor P.C. boards

Procedures and notes for replacing indoor unit P.C. boards, including EEPROM handling.

Detachments

8-1. 1-way cassette (SH)

Procedures for detaching parts like air intake grille, electrical parts cover, ceiling panel, and control P.C. board.

8-2. Compact 4-way cassette

Procedures for detaching parts like air intake grille, electric parts cover, and adjust corner cover.

8-3. Slim duct

Procedures for detaching air filter and plate inlets from slim duct units.

8-4. Concealed duct standard

Procedures for detaching electrical control box and sirocco fan assembly.

8-5. Concealed duct high static pressure

Procedures for replacing the fan motor.

8-6. Ceiling

Procedures for detaching intake grille and electrical control cover.

8-7. Floor standing

Procedures for removing electrical component assembly, heat exchanger, and fan assembly.

8-8. Floor standing cabinet

Procedures for removing the electrical control assembly and heat exchanger.

Exploded Diagram / Service Parts List

9-1. 1-way cassette type (YH)

Exploded views and parts lists for 1-way cassette (YH) models.

9-2. 1-Way cassette type (SH)

Exploded views and parts lists for 1-way cassette (SH) models.

9-3. Compact 4-way cassette type

Exploded views and parts lists for compact 4-way cassette models.

9-4. Slim duct type

Exploded views and parts lists for slim duct models.

9-5. Concealed duct standard type

Exploded views and parts lists for concealed duct standard models.

9-6. Concealed duct high static pressure type

Exploded views and parts lists for concealed duct high static pressure models.

9-7. Ceiling type

Exploded views and parts lists for ceiling type models.

9-8. Floor standing type

Exploded views and parts lists for floor standing models.

9-9. Floor standing concealed type

Exploded views and parts lists for floor standing concealed models.

9-10. Floor standing cabinet type

Exploded views and parts lists for floor standing cabinet models.

Related product manuals