Do you have a question about the Toshiba MMU-AP0241H and is the answer not in the manual?
Heating Capacity | 8.0 kW |
---|---|
Refrigerant | R410A |
Cooling Capacity (BTU) | 24, 000 BTU |
Operating Temperature Range (Cooling) | 18°C to 46°C |
Operating Temperature Range (Heating) | -15°C to 24°C |
Power Supply | 220-240V |
Lists various types of indoor units for the system, including cassette and duct types.
Lists available models for outdoor units.
Safety warnings regarding incorrect installation procedures and practices.
Precautions for safe operation, avoiding injuries from internal parts and recognizing operational issues.
Safety guidelines for moving, repairing, or modifying the air conditioner to prevent hazards.
Installation cautions related to drainage, earthing, flammable gas, and securing the unit.
Identification of parts for various indoor unit styles like cassette and wall-mounted.
Identification of components and connection points on the outdoor unit.
Explanation of remote controller displays and buttons for operation.
Steps and requirements before the first operation of the air conditioner.
Guidance on setting airflow direction for cooling and heating operations.
Procedures for setting and cancelling various timer operations for the unit.
Guidelines for choosing a suitable and safe installation site.
Safety precautions and requirements for electrical wiring installation.
Instructions on how and when to clean the air filter.
Pre-operation checks for ensuring correct function and safety.
Performance characteristics during cooling/heating and operation limits.
Critical warnings about the dangers of improper re-installation.
Procedure to check past error codes and system history.
List of included accessory parts for the unit installation and operation.
Important safety cautions before installation.
List of necessary tools and essential handling precautions for R410A refrigerant.
Required clearances and space considerations for unit installation and service.
Instructions for ensuring proper drainage for the outdoor unit, especially in heating mode.
Procedures and requirements for connecting refrigerant pipes to the unit.
Methods and specifications for flaring and connecting refrigerant pipes.
Guidelines for designing the electrical wiring, including combined outdoor units.
Table detailing wire sizes and fuses based on unit capacity.
Procedure for automatic address setup for indoor units in a system.
Method for manually setting indoor unit addresses using the remote controller.
Steps to set the item code for connecting multiple indoor units to a single FS unit.
Steps to configure a specific indoor unit for cooling-only operation.
Procedure for conducting a test operation of the air conditioner.
Guide to diagnosing issues using segment displays and check codes on the outdoor unit.
Detailed list of outdoor unit check codes and their meanings.
List of included accessory parts for the unit installation and operation.
General safety precautions to be observed during installation and operation.
Visual representation of the Flow Selector unit with dimensions.
Procedures for installing hanging bolts for the Flow Selector unit.
Limits on pipe length and height difference between units.
Procedures for airtight testing, air purging, and leak checks.
Important notes regarding control and power wires between units.