EasyManua.ls Logo

Toshiba MMU-UP0301HP-E User Manual

Toshiba MMU-UP0301HP-E
295 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AIR CONDITIONER (MULTI TYPE)
SERVICE MANUAL
Indoor unit
<4-way cassette type>
MMU-UP0091HP-E(TR)
MMU-UP0121HP-E(TR)
MMU-UP0151HP-E(TR)
MMU-UP0181HP-E(TR)
MMU-UP0241HP-E(TR)
MMU-UP0271HP-E(TR)
MMU-UP0301HP-E(TR)
MMU-UP0361HP-E(TR)
MMU-UP0481HP-E(TR)
MMU-UP0561HP-E(TR)
<Ceiling type>
MMC-UP0151HP-E(TR)
MMC-UP0181HP-E(TR)
MMC-UP0241HP-E(TR)
MMC-UP0271HP-E(TR)
MMC-UP0361HP-E(TR)
MMC-UP0481HP-E(TR)
MMC-UP0561HP-E(TR)
<Concealed Duct Standard type>
MMD-UP0051BHP-E
MMD-UP0071BHP-E(TR)
MMD-UP0091BHP-E(TR)
MMD-UP0121BHP-E(TR)
MMD-UP0151BHP-E(TR)
MMD-UP0181BHP-E(TR)
MMD-UP0241BHP-E(TR)
MMD-UP0271BHP-E(TR)
MMD-UP0301BHP-E(TR)
MMD-UP0361BHP-E(TR)
MMD-UP0481BHP-E(TR)
MMD-UP0561BHP-E(TR)
<Concealed Duct High Static Pressure type>
MMD-UP0181HP-E(TR)
MMD-UP0241HP-E(TR)
MMD-UP0271HP-E(TR)
MMD-UP0361HP-E(TR)
MMD-UP0481HP-E(TR)
MMD-UP0561HP-E(TR)
MMD-UP0721HP-E(TR)
MMD-UP0961HP-E(TR)
<Concealed Duct High Static Pressure
fresh air intake type>
MMD-UP0481HFP-E(TR)
MMD-UP0721HFP-E(TR)
MMD-UP0961HFP-E(TR)
MMD-UP1121HFP-E(TR)
MMD-UP1281HFP-E(TR)
<Console type>
MML-UP0071NHP-E(TR)
MML-UP0091NHP-E(TR)
MML-UP0121NHP-E(TR)
MML-UP0151NHP-E(TR)
MML-UP0181NHP-E(TR)
<High wall type>
MMK-UP0031HP-E(TR)
MMK-UP0051HP-E(TR)
MMK-UP0071HP-E(TR)
MMK-UP0091HP-E(TR)
MMK-UP0121HP-E(TR)
MMK-UP0151HP-E(TR)
MMK-UP0181HP-E(TR)
MMK-UP0241HP-E(TR)
MMK-UP0031HPL-E(TR)
MMK-UP0051HPL-E(TR)
MMK-UP0071HPL-E(TR)
MMK-UP0091HPL-E(TR)
MMK-UP0121HPL-E(TR)
MMK-UP0151HPL-E(TR)
MMK-UP0181HPL-E(TR)
MMK-UP0241HPL-E(TR)
FILE NO. SVM-20095
January, 2021

Table of Contents

Other manuals for Toshiba MMU-UP0301HP-E

Questions and Answers:

Toshiba MMU-UP0301HP-E Specifications

General IconGeneral
BrandToshiba
ModelMMU-UP0301HP-E
CategoryAir Conditioner
LanguageEnglish

Summary

Precautions for Safety

Definition of Qualified Installer or Service Person

Defines the qualifications and knowledge required for qualified installers and service personnel.

Definition of Protective Gear

Details the protective gear required for various work tasks, including general and specific safety clothing.

Warning Indications on Air Conditioner Unit

Explains the meaning and importance of warning labels found on the air conditioner unit.

Electrical Shock Hazard Precautions

Highlights dangers of electric shock and mandatory safety measures before performing work.

General Safety Warnings

Provides general warnings regarding refrigerant handling, electrical work, and working at heights.

Specifications

1-1. 4-Way Cassette Type Specifications

Detailed technical specifications for 4-way cassette type indoor units.

1-2. Ceiling Type Specifications

Detailed technical specifications for ceiling type indoor units.

1-3. Concealed Duct Standard Type Specifications

Detailed technical specifications for concealed duct standard type indoor units.

1-4. Concealed Duct High Static Pressure Type Specifications

Detailed technical specifications for concealed duct high static pressure type indoor units.

1-5. Concealed Duct High Static Pressure Fresh Air Intake Type Specifications

Detailed technical specifications for concealed duct high static pressure fresh air intake type units.

1-6. Console Type Specifications

Detailed technical specifications for console type indoor units.

1-7. High Wall Type Specifications

Detailed technical specifications for high wall type indoor units.

Construction Views (External Views)

2-1. 4-Way Cassette Type Views

External views and dimensions for 4-way cassette type indoor units.

2-2. Ceiling Type Views

External views and dimensions for ceiling type indoor units.

2-3. Concealed Duct Standard Type Views

External views and dimensions for concealed duct standard type indoor units.

2-4. Concealed Duct High Static Pressure Type Views

External views and dimensions for concealed duct high static pressure type indoor units.

2-5. Concealed Duct High Static Pressure Fresh Air Intake Type Views

External views and dimensions for concealed duct high static pressure fresh air intake type units.

2-6. Console Type Views

External views and dimensions for console type indoor units.

2-7. High Wall Type Views

External views and dimensions for high wall type indoor units.

Wiring Diagrams

3-1. 4-Way Cassette Type Wiring

Wiring diagram for the 4-way cassette type indoor unit.

3-2. Ceiling Type Wiring

Wiring diagram for the ceiling type indoor unit.

3-3. Concealed Duct Standard Type Wiring

Wiring diagram for the concealed duct standard type indoor unit.

3-4. Concealed Duct High Static Pressure Type Wiring

Wiring diagram for the concealed duct high static pressure type indoor unit.

3-5. Concealed Duct High Static Pressure Fresh Air Intake Type Wiring

Wiring diagram for concealed duct high static pressure fresh air intake type units.

3-6. Console Type Wiring

Wiring diagram for the console type indoor unit.

3-7. High Wall Type Wiring

Wiring diagram for the high wall type indoor unit.

Parts Rating

4-Way Cassette Type Parts

Parts list and rating for 4-way cassette type indoor units.

Ceiling Type Parts

Parts list and rating for ceiling type indoor units.

Concealed Duct Standard Type Parts

Parts list and rating for concealed duct standard type indoor units.

Concealed Duct High Static Pressure Type Parts

Parts list and rating for concealed duct high static pressure type indoor units.

Concealed Duct High Static Pressure Fresh Air Intake Type Parts

Parts list and rating for concealed duct high static pressure fresh air intake type units.

Console Type Parts

Parts list and rating for console type indoor units.

High Wall Type Parts

Parts list and rating for high wall type indoor units.

Refrigerant Cycle Diagram

Indoor Unit Refrigerant Cycle

Diagram illustrating the refrigerant cycle for the indoor unit and functional parts.

Control Outline

When Power Supply is Reset

Details how the system behaves when power supply is reset.

Operation Mode Selection

Explains how to select operation modes via remote controller commands.

Room Temperature Control

Covers adjustment ranges for room temperature control via remote controller.

Fan Speed Selection

Describes fan speed selection based on remote control commands and temperature differences.

Freeze Prevention Control

Details freeze prevention control logic based on TC1, TC2, and TCJ sensor readings.

Communication Type, Model Names, and Connectable Units

Communication Specifications and Model Names

Details communication types (TU2C-Link, TCC-Link) and corresponding model names.

Wiring Specifications for Combined Systems

Explains wiring and unit connection changes when combining TU2C-Link and TCC-Link systems.

Applied Control and Functions

8-1. Indoor Controller Block Diagram (MCC-1643)

Block diagram illustrating the connections for MCC-1643 indoor controller with wired remote.

8-2. Indoor Controller Block Diagram (MCC-1720)

Block diagram illustrating the connections for MCC-1720 indoor controller with wired remote.

8-3. Indoor Controller Block Diagram (MCC-1696)

Block diagram illustrating the connections for MCC-1696 indoor controller with wired remote.

8-4. Indoor Print Circuit Board

Detailed diagrams of the indoor unit print circuit boards (MCC-1643, MCC-1720, MCC-1696).

8-5. Test Run of Indoor Unit

Procedure for performing cooling/heating test runs using wired and wireless remote controllers.

8-6. Method to Set Indoor Unit Function DN Code

Step-by-step guide for setting indoor unit functions and DN codes via remote controller.

8-7. Applied Control of Indoor Unit

Details on control systems using remote location ON/OFF control boxes.

Troubleshooting

9-1. Overview of Troubleshooting

General information on troubleshooting, applicable models, tools, and normal behaviors.

9-2. Troubleshooting Method

Methodology for identifying trouble sites using check codes and displays.

9-3. Troubleshooting Based on Remote Controller Display

Guide to troubleshooting issues based on information displayed on the remote controller.

9-4. Check Codes Displayed on Remote Controller and Outdoor Unit

Lists check codes displayed on remote controllers and outdoor units with troubleshooting steps.

9-5. Diagnostic Procedures for Indoor Unit Check Codes

Flowcharts for diagnosing common check codes for indoor units.

9-6. Sensor Characteristics

Graphs and tables showing resistance characteristics of various indoor unit sensors.

9-7. Maintenance List

Recommended maintenance schedule for indoor and outdoor units.

P.C. Board Exchange Procedures

10-1. Replacement of Indoor P.C. Boards

Procedures for replacing the indoor unit P.C. board, including data backup and restoration.

Detachments

11-1. 4-Way Cassette Type Detachments

Step-by-step procedures for detaching parts of the 4-way cassette type indoor unit.

11-2. Ceiling Type Detachments

Step-by-step procedures for detaching parts of the ceiling type indoor unit.

11-3. Concealed Duct Standard Type Detachments

Step-by-step procedures for detaching parts of the concealed duct standard type indoor unit.

11-4. Concealed Duct High Static Pressure Type Detachments

Step-by-step procedures for detaching parts of the concealed duct high static pressure type indoor unit.

11-5. Concealed Duct High Static Pressure Fresh Air Intake Type Detachments

Step-by-step procedures for detaching parts of the concealed duct high static pressure fresh air intake type units.

11-6. Console Type Detachments

Step-by-step procedures for detaching parts of the console type indoor unit.

11-7. High Wall Type Detachments

Step-by-step procedures for detaching parts of the high wall type indoor unit.

Exploded Views and Parts List

12-1. 4-Way Cassette Type Exploded View

Exploded view and parts list for 4-way cassette type indoor units.

12-2. Ceiling Type Exploded View

Exploded view and parts list for ceiling type indoor units.

12-3. Concealed Duct Standard Type Exploded View

Exploded view and parts list for concealed duct standard type indoor units.

12-4. Concealed Duct High Static Pressure Type Exploded View

Exploded view and parts list for concealed duct high static pressure type indoor units.

12-5. Concealed Duct High Static Pressure Fresh Air Intake Type Exploded View

Exploded view and parts list for concealed duct high static pressure fresh air intake type units.

12-6. Console Type Exploded View

Exploded view and parts list for console type indoor units.

12-7. High Wall Type Exploded View

Exploded view and parts list for high wall type indoor units.

Related product manuals