EasyManua.ls Logo

Toshiba Portege M780 - Page 290

Toshiba Portege M780
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tests and Diagnostics
3-178 [CONFIDENTIAL] PORTEGE M780 Maintenance Manual (960-809)
Result Status 1
7 6 5 4 3 2 1 0
EN DE OR ND NW MR
EN End of Cylinder
DE
Data error
OR
Over run (DMAC)
ND
No data
NW
Not writable
MA
Missing address mark
Result Status 2
7 6 5 4 3 2 1 0
CM DD NC SH SN BC MD
CM Control mark
DD
Data error (data field)
NC
No cylinder
SH
Scan equal hit
SN
Scan not satisfied
BC
Bad cylinder
MD
Missing address mark (data field)