Unit model Indoor
RAS -13BKV-E
Outdoor
RAS -13BAV-E
Cooling capacity (kW)
Cooling capacity range (kW)
Heating capacity (kW)
Heating capacity range (kW)
Power supply
1Ph/50Hz/220-240V
Electric Indoor Operation mode Co o ling H ea ting
characteristic Running current (A) 0.22-0.20 0.23-0.21
Power consumption (W) 34 35
Power factor (%) 70 69
Outdoor Operation mode Cooling Heating
Running current (A) 5.38-4.95 4.52-4.14
Power consumption (W) 1116 925
Power factor (%) 94 93
Starting current (A)
COP (Cooling / Heating) 2.70/3.75
Operating Indoor High (Cooling / Heating) (dB-A) 41/42
noise Medium (Cooling / Heating) (dB-A) 33/34
Low (Cooling / Heating) (dB-A) 24/24
Outdoor (Cooling / Heating) (dB-A) 48/50
Indoor unit Unit model
RAS-13BKV-E
Dimension Height (mm) 293
Width (mm) 798
Depth (mm) 230
Net weight (kg) 9
Fan motor output (W) 22
Air flow rate (Cooling / Heating)
(m
3
/ min)
10.0/10.3
Outdoor unit Unit model
RAS-13BAV-E
Dimension Height (mm) 530
Width (mm) 660
Depth (mm) 240
Net weight (kg) 22
Compressor Motor output (W) 750
Type
Model NX89F0F-20D
Fan motor output (W) 43
Air flow rate (Cooling / Heating)
(m
3
/ min)
33/33
Piping Type Flare connection
connection Indoor unit Liquid side (mm)
6.35
Gas side (mm)
9.52
Outdoor unit Liquid side (mm)
6.35
Gas side (mm)
9.52
Maximum length (m) 15
Maximum charge-less length (m) 15
Maximum height difference (m) 12
Refrigerant Name of refrigerant R410A
Weight (kg) 0.58
Wiring Power supply 3 Wires: Includes earth (Outdoor)
connection Interconnection 4 Wires: Includes earth
Usable temperature range Indoor (Cooling / Heating)
(C)
21-32/0-28
Outdoor (Cooling / Heating)
(C)
-15,46/-15,24
* The specification may be subject to change without notice for purpose of improvement.
0.70-4.50
0.75-3.50
3.60
3.10
5.60 4.75
2-2. Specification
Twin rotary type with DC-inverter variable speed control to Single
rotary type with DC-inverter variable speed control
FILE NO. SVM-16003