Do you have a question about the Toshiba RAS-09EKV-UL and is the answer not in the manual?
Power Supply | 220-240 V, 50 Hz |
---|---|
Refrigerant | R410A |
Weight (Indoor Unit) | 9 kg |
Type | Wall Mounted |
Heating Capacity | 9000 BTU/h |
Outdoor Unit Noise Level | 48 dB |
Precautions for installing new refrigerant R410A air conditioners, including handling, pressure, and oil.
Detailed specifications for indoor and outdoor units including dimensions, weight, and performance data.
Safety precautions and procedures for handling R410A refrigerant during installation and servicing.
Guidelines for installing refrigerant piping, including materials, joints, and processing.
Exploded view and dimensions of the indoor unit, showing components and locations.
Exploded view and dimensions of the outdoor unit, detailing component placement.
Wiring diagram for the RAS-09EKV-UL indoor unit and RAS-09EAV-UL outdoor unit.
Wiring diagram for the RAS-09EKV-UL indoor unit and RAS-09EAV2-UL outdoor unit.
Wiring diagram for the RAS-12EKV-UL indoor unit and RAS-12EAV-UL outdoor unit.
Wiring diagram for the RAS-12EKV-UL indoor unit and RAS-12EAV2-UL outdoor unit.
List of electrical parts for the indoor unit with their specifications and ratings.
List of electrical parts for the outdoor unit with their specifications and ratings.
Diagram illustrating the refrigerant flow and major components for RAS-09EKV-UL/RAS-09EAV-UL.
Diagram showing the refrigerant cycle and components for RAS-12EKV-UL/RAS-12EAV2-UL.
Block diagram showing control functions and signals for the indoor unit and remote controller.
Block diagram illustrating control logic and components of the outdoor unit's inverter assembly.
Overview of the air conditioner's control system, including indoor/outdoor unit roles.
Details on basic operation control, including remote controller input and unit status.
Controls indoor fan speed in cooling and heating modes, with detailed procedures.
Describes how outdoor fan speed is controlled based on indoor commands and conditions.
Adjusts cooling or heating capacity based on load by controlling compressor revolution.
Protective control for indoor heat exchanger to prevent freezing or overpressure.
Procedure for defrost operation to remove frost from the outdoor heat exchanger.
Controls the air direction of the indoor unit, including position and adjustment.
Eco operation mode for cooling and heating, adjusting settings for energy saving.
Starts or stops the unit using the RESET button without the remote control.
Controls throttle amount of refrigerant and valve opening degree based on operating status.
Diagram showing the physical layout and clearances for installing indoor and outdoor units.
Details on installation procedures, including supplied parts and tools.
Guidelines for selecting an appropriate installation location for the outdoor unit.
Criteria for selecting the indoor unit installation location, focusing on clearances.
Procedure for evacuating air from the system using a vacuum pump.
Initial confirmation steps including power supply and voltage checks.
Diagnoses problems based on the flashing patterns of the indoor unit's indicator lamps.
Guide on using the remote controller in service mode for self-diagnosis.
Troubleshooting flowchart for diagnosing problems based on specific symptoms.
Steps to diagnose outdoor unit issues by checking power supply and voltage.
Procedures for checking main parts like the P.C. board and sensors.
Procedure to diagnose the condition of the outdoor fan motor.
General precautions and step-by-step guide for disassembling the indoor unit.
General procedure to access and replace the microcomputer or P.C. board.
Steps for detaching and attaching major components of the outdoor unit.
Exploded view and parts list for the indoor unit's E-Part.
Exploded view and parts list for various components of the indoor unit.
Exploded view and parts list for outdoor unit models RAS-09,12EAV-UL.
Exploded view and parts list for outdoor unit models RAS-09,12EAV2-UL.
Lists indoor and outdoor unit models and their compatibility.
Detailed specifications for various models, including capacity, power, dimensions, and noise.
Dimensional drawings and measurements for RAS-09EKV-UL and RAS-12EKV-UL indoor units.
Dimensional drawings and measurements for RAS-15/17/22EKV-UL indoor units.
Dimensional drawings and measurements for outdoor units.
Table showing part load performance data for cooling and heating based on temperatures.
Part load performance data for RAS-12EKV-UL/RAS-12EAV2-UL models under various conditions.
Part load performance data for RAS-15EKV-UL/RAS-15EAV2-UL models under various conditions.
Part load performance data for RAS-17EKV-UL/RAS-17EAV2-UL models under various conditions.
Part load performance data for RAS-22EKV-UL/RAS-22EAV2-UL models under various conditions.
Table showing heat capacity trends based on indoor and outdoor air temperatures.
Heat capacity trends for RAS-12EKV-UL/RAS-12EAV2-UL based on temperature.
Heat capacity trends for RAS-15EKV-UL/RAS-15EAV2-UL based on temperature.
Chart showing cooling air throw patterns for RAS-09EKV-UL.
Chart showing heating air throw patterns for RAS-09EKV-UL.
Chart showing cooling air throw patterns for RAS-12EKV-UL.
Chart showing heating air throw patterns for RAS-12EKV-UL.
Chart showing cooling air throw patterns for RAS-15EKV-UL.
Chart showing heating air throw patterns for RAS-15EKV-UL.
Chart showing cooling air throw patterns for RAS-17EKV-UL.
Chart showing heating air throw patterns for RAS-17EKV-UL.
Chart showing cooling air throw patterns for RAS-22EKV-UL.
Chart showing heating air throw patterns for RAS-22EKV-UL.
Graph of sound levels vs. sound frequency for cooling operation.
Graph of sound levels vs. sound frequency for heating operation.
Data and graphs showing cooling performance at various conditions.
Data and graphs illustrating heating performance across different conditions.
Identifies and labels all buttons on the standard wireless remote controller.
Lists model names and details about °F/°C display options for wired controllers.