9
4-3. Outdoor Unit (RAS-09SASX-1)
FILE NO. SVM-08028
No. Parts name Type
Output (Rated) 780W, 2 poles, 1 phase, 220 - 240 V~, 50H
z
Winding resistance ()
C-R C-S
(at 20ºC) 3.51 3.67
Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V~, 50Hz
Winding resistance ()
Red-Black White-Black
(at 20ºC) 410 435
Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
Winding resistance ()
Red-Black White-Black
(at 20ºC) 235.2 260.1
Running capacitor
(for fan motor)
Running capacitor
(for compressor)
4 RS44B356U0215S
AC 440 V~, 35µF
5 Overload relay U/T : 6.1A (80ºC), Open : 135±5ºC, Close : 75±11ºC
DS451155NPQB
AC 450 V~, 1.5µF
3
WLF-240-20A
(Type "A")
SKF-240-20B
(Type "B")
Fan motor (for outdoor)2
Specifications
QK164PBA
Compressor1
LPAP960B