10-2. Optional Parts, Accessories and Tools
10-2-1. Optional Installation Parts
Fig. 10-2-1
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
Use ∅ 8 mm or ∅ 10 mm anchor bolts and nuts.
•
•
If it is necessary to drain the defrost water, attach drain nipple 9 and cap water proof 1
0 to the
•
bottom plate of the outdoor unit before installing it.
A
Air inlet
Air outlet
Drain outlet
600 mm
90 mm
125 mm108 mm
28 mm
86 mm
102 mm
320 mm
25 mm
∅
Parts name
Refrigerant piping
Liquid side : ∅6.35 mm
Gas side : ∅9.52 mm
Pipe insulating material
(polyethylene foam, 8 mm thick)
Putty, PVC tapes
Part
Code Q'ty
One
each
1
One
each
12.70 mm∅
(RAS-(B) 10,13UFV Series)
(RAS-(B) 18UFV Series)
B
C
<Fixing bolt arrangement of outdoor unit>
* Drain nipple and cap
water proof are packed
in outdoor unit.
When using a multi-system outdoor unit is used, refer to the installation manual provided with
the model concerned.
– 66 –