EasyManua.ls Logo

Toshiba RAS-10UKP-E4 - Page 7

Toshiba RAS-10UKP-E4
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 6 -
Capacity
Phase 1Æ
Power source V 220 - 240
Hz 50
Power consumption kW 1.24 1.28 0.80 0.85
Power factor % 98 95 97 95
Running Indoor A 0.15
current Outdoor A 5.60 5.45 3.60 3.58
Starting current A 24 16
Moisture removal lit/h 2.0 1.2
Noise
Indoor (H/M/L) dB 41/35/31 39/33/26
Outdoor dB 47 48 44 45
Refrigerant
Name of refrigerant R22
Rated amount kg 0.80 0.68
Refrigerant control Capillar y tube
Gas side size mm Æ12.70 Æ9.52
Connection type Flare connection
Liquid side size mm 6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 15*
1
10*
1
(One way)
Maximum height
6 5
difference
INDOOR UNIT RAS-13UKPX4 RAS-12UKPX4 RAS-10UKPX4
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 630 610
Air volume Medium fan m
3
/h 520 460
Low fan m
3
/h 430 340
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-13UAX4 RAS-12UAX4 RAS-10UAX4
Height mm 550
Dimensions Width mm 780
Depth mm 270
Net weight kg 34 31
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 2030 2150 1740 1850
Fan motor output W 30 20
Compressor
Model PH225X2C-4FT RM5510GNE94
Output W 1100 750
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 21 ~ 43
MODEL
RAS-13UKPX4 / RAS-13UAX4 RAS-12UKPX4 / RAS-12UAX4 RAS-10UKPX4 / RAS-10UAX4
ITEM Cooling
220 V 240 V 220 V 240 V
kW 3.70 3.75 2.65 2.70
220 V
240 V
3.483.40
1.24
1.28
98 95
5.60 5.45
47 48
2030
2150
m
FILE NO. SVM-05001

Table of Contents

Related product manuals