6-1. Indoor Unit
6-2. Outdoor Unit
No. Parts name Type Specifications
RPG-240-25A
AC 240V, 25W
2 Room temp. sensor (TA-sensor) ( - ) 10kΩ at 25°C
3 Heat exchanger temp. sensor (TC-sensor) ( - ) 10kΩ at 25°C
4 Louver motor 24BYJ48-HTP Output (Rated) 1W, 16 poles, DC12V
1
Fan motor
(for indoor)
6. SPECIFICATIONS OF ELECTRICAL PARTS
FILE NO. SVM-13092
– 18 –
No. Parts name Type Specifications
L = 19mH, 10A
2 Outdoor fan motor ICF-140-43-4R DC140V, 43W
3 Suction temp. sensor (TS sensor) (Inverter attached) 10kΩ (25°C)
4 Discharge temp. sensor (TD sensor) (Inverter attached) 62kΩ (20°C)
5 Outside air temp. sensor (TO sensor) (Inverter attached) 10kΩ (25°C)
6 Heat exchanger temp. sensor (TE sensor) (Inverter attached) 10kΩ (25°C)
Reactor
1
20A, AC250V
ASM89D16UEZ
PQ-M01012-000082
SQ-A2522G-000352
3-phases 4-poles 750W
DC12V
AC220-240V
Coil for 4-way valve
COIL FOR P.M.V.
Compressor
Terminal block (5P)7
8
9
10
CH-69-Z-T