– 5 –
Unit model Indoor  RAS-10N3AV2-A
Outdoor  RAS-10N3AV2-A
Cooling capacity (kW)  2.5
Cooling capacity range (kW)  1.1-3.1
Heating capacity (kW)   3.2
Heating capacity range (kW)   0.9-4.8
Power supply
Electric Indoor Operation mode  Cooling     Heating
characteristic Running current (A)                  0.21-0.19                             0.24-0.22
Power consumption (W)  35  40
Power factor (%) 76 76
Outdoor Operation mode  Cooling  Heating
Running current (A)   2.81-2.58   3.43-3.14
Power consumption (W)     563                                                 710
Power factor (%) 91                                   94
Starting current (A)  3.67
COP (Cooling / Heating)
Operating Indoor High (Cooling / Heating) (dB-A)   39/39
noise Medium (Cooling / Heating) (dB-A)    33/34
Low (Cooling / Heating) (dB-A)   26/28
Outdoor (Cooling / Heating) (dB-A)    
 46/47
Indoor unit Unit model   RAS-10N3KV2-A
Dimension Height (mm) 275
Width (mm)   790
Depth (mm)   225
Net weight (kg)                                                                 10
Fan motor output (W)   20
Air flow rate (Cooling / Heating) 
(m
3 
 min)  
8.6/9.5
Outdoor unit Unit model  RAS-10N3AV2-A
Dimension Height (mm)    550
Width  (mm)     780
Depth (mm)    290
Net weicht (kg)  33
Compressor  Motor output  (W)     750
Type Single rotary type with DC-inverter variable speed conrol
Model  DA89X1C-23FZ2
Fan motor output (W)
Air flow rate (Cooling / Heating) 
(m
3 
 min) 
30/30
Piping  Type   Flare connection
connection Indoor unit Liquid side (mm) 
     ∅6.35
Gas side (mm) 
    ∅9.52
Outdoor unit Liquid side (mm) 
    ∅6.35
Gas side (mm) 
  ∅9.52
Maximum length (m)    20
Maximum charge-less length  (m)                                              15
Maximum height difference  (m)                                              10
Refrigerant  Name of refrigerant                                              R410A
Weight (kg)    0.80
Wiring Power supply
connection Interconnection
Usable temperature range  Indoor  (Cooling / Heating) 
(
o
C) 
  21-32/0-28
Outdoor (Cooling / Heating) 
(
o
C) 
  -10-46/-15-24
Accessory  Indoor unit  Installation plate                                              1
Wireless remote controller    1
batteries    2
Remote controller holder    1
TOSHIBA IAQ Filter (long type)                                              1
Mounting screw
   6 (∅ 4 x 25L)
Pan head wood screw 
   2 (∅ 3.1 x 16L)
Plasma air purifier    -
Installation manual                                              1
Owner's manual                                              1
Outdoor unit  Drain nipple                                              1
Water proof rubber cap                                              2
* The specification may be subject to change without notice for purpose of improvement.
3 Wires: Includes earth (Outdoor)
4 Wires: Includes earth 
4.18/4.27
1Ph/50Hz/220-240V
43
Specification
FILE NO. SVM-13001
2. SPECIFICATIONS