CAUTION
10-5. Others
Check the flare nut connections for the gas leak with
a gas leak detector or soap water.
Fig. 10-5-1
10-5-1. Gas leak test
Check places
for outdoor unit
Check places for
indoor unit (Flarenut
connection)
10-5-2. Remote Control A-B Selection
When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may
receive the remote control signal simultaneously and
operate. In this case, the operation can be preserved
by setting either one remote control to B setting.
(Both are set to A setting in factory shipment.)
The remote control signal is not received when the
settings of indoor unit and remote control are different.
There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
<Remote control A-B selection>
To separate using of remote control for each indoor unit
in case of 2 air conditioners are installed nearly.
<Remote Control B Setup>
1. Press [RESET] button on the indoor unit to turn the air
conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control
by the tip of the pencil. "00" will be shown on the display
4. Press [MODE] during pushing [CHECK]. "B" will show
on the display and "00" will disappear and the air
conditioner will turn OFF. The Remote Control B
is memorized [Picture ).
(Picture )
1
2
Fig. 10-5-2
NOTE : 1. Repeat above step to reset Remote
Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
12
FILE NO. SVM-13001
Wrong wiring connection may cause some electrical
parts burn out.
Be sure to comply with local cords on running the
wire from indoor unit to outdoor unit (size of wire
and wiring method, etc.)
Every wire must be connected firmly.
This installation circuit breaker must be used specified
for the power supply line of this air conditioner.
If incorrect or incomplete wiring is carried out, it will
cause an ignition or smoke.
Prepare the power supply for exclusive use with the
air conditioner.
This product can be connected to the mains.
Connection to fixed wiring: A switch which
disconnects all poles and has a contact separation
of at least 3 mm must be incorporated in the fixed wiring
67