Do you have a question about the Toshiba RAS-13NKP-E2 and is the answer not in the manual?
Cooling Capacity | 3.5 kW |
---|---|
Heating Capacity | 4.0 kW |
Energy Efficiency Ratio (EER) | 3.21 |
Refrigerant | R410A |
Power Supply | 220-240V, 50Hz |
Coefficient of Performance (COP) | 3.61 |
Outdoor Unit Noise Level | 50 dB |
Detailed diagrams of the indoor unit with dimensions and installation points.
Diagrams of the outdoor unit, including installation dimensions and views.
Wiring diagram for specific models RAS-13NKHP-E2 / RAS-13N2AH-E.
Wiring diagram for specific models RAS-13NKP-E / RAS-13N2A-E.
Wiring diagram for specific models RAS-13NKPX, RAS-12NKPX-V.
Wiring diagram for specific models RAS-13NKP-HX / RAS-13N2A-HX.
Wiring diagram for specific models RAS-10NKP-HX / RAS-10N2A-HX.
Specifications for electrical parts of the indoor unit model RAS-13NKHP-E2.
Specifications for electrical parts of the outdoor unit model RAS-13N2AH-E.
Specifications for electrical parts of multiple indoor unit models.
Specifications for electrical parts of multiple outdoor unit models.
Specifications for electrical parts of outdoor unit model RAS-13N2A-HX.
Specifications for electrical parts of outdoor unit model RAS-10N2A-HX.
Refrigeration cycle diagram for specific models RAS-13NKHP-E2 / RAS-13N2AH-E.
Refrigeration cycle diagram for multiple models.
Refrigeration cycle diagram for specific models RAS-13NKP-HX / RAS-13N2A-HX.
Refrigeration cycle diagram for specific models RAS-10NKP-HX / RAS-10N2A-HX.
Control block diagram for specific models RAS-13NKHP-E2 / RAS-13N2AH-E.
Control block diagram for multiple air conditioner models.
Overview of how the air conditioner's control system operates and its components.
Detailed description of various operation circuits and their functions.
Explanation of the Hi POWER mode operation and its features.
High-temperature limit control to prevent refrigerating cycle issues.
Low-temperature limit control to prevent indoor heat exchanger freezing.
Details on defrost operation to melt ice during heating mode.
Current limit control to prevent exceeding specified values by managing outdoor fan.
Automatic restarting function after power supply interruption.
Filter check lamp notification for maintenance after 1000 hours.
Function to reduce humidity and prevent mold formation inside the unit.
System to control indoor fan speed for reduced noise levels.
Mode that saves energy by automatically adjusting room temperature.
Important safety precautions to follow during installation.
Diagrams illustrating the installation of indoor and outdoor units.
Details on installation procedures and optional parts.
Procedures and considerations for installing the indoor unit.
Guidelines for selecting an appropriate installation location for the outdoor unit.
Guide on how to set the remote control selector switch.
Other installation-related topics, including gas leak test and test operation.
General procedure for troubleshooting issues with the air conditioner.
Basic check items to perform before troubleshooting.
Issues arising from incorrect cable connections between units.
How the microcontroller controls operations according to programmed logic.
Initial assessment of problems based on symptoms and basic checks.
Diagnosis of failures indicated by lamps on the indoor unit display.
Using the remote control for self-diagnosis and check codes.
Flowcharts for diagnosing and resolving specific operational issues.
Troubleshooting steps when power is not turned on after replacing the PC board.
Troubleshooting steps when the outdoor unit does not operate.
Troubleshooting steps when only the compressor does not operate.
Troubleshooting steps when only the outdoor fan does not operate.
Troubleshooting steps when the 4-way valve does not operate during heating.
Troubleshooting steps when only the indoor fan does not operate.
Troubleshooting steps for the remote control and indoor PC board issues.
Procedures and precautions for checking the P.C. board for defects.
Procedures for replacing parts of the indoor unit.
Procedures for replacing parts of the outdoor unit.
Exploded views and parts list for Indoor Unit (E-Parts Assy) for RAS-13NKHP-E2.
Exploded views and parts list for Indoor Unit (E-Parts Assy) for RAS-13NKP-E2.
Exploded views and parts list for multiple Indoor Unit models.
Exploded views and parts list for Indoor Unit models RAS-13NKHP-E2, RAS-13NKP-E2.
Exploded views and parts list for Indoor Unit models RAS-13NKPX, RAS-12NKPX-V, RAS-13NKP-HX, RAS-10NKP-HX.
Exploded views and parts list for Indoor Unit model RAS-13N2AH-E.
Exploded views and parts list for multiple Indoor Unit models.