- 15 -
FILE NO. SVM-06001
4-3. Indoor Unit (RAS-13NKP-E2, RAS-13NKPX, RAS-12NKPX-V,
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF- 220-20-4A-1 AC Motor with 150 C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Transformer
4 Microcontroller unit (IC30) TMP87CM40AN
5 Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01) *SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB50) KBP06M/51 1.5A, 600 V
8 Capacitor (C50) PF1E222MNN1625 2200mF, 25 V
9 Fuse (F01) BET6.3A T6.3A, 250VAC
10 Varistor (R21, R22) TND15G561K 560 V
11 Louver motor MP24Z 12VDC
12 Relay (Comp., RY01) DI1U Rating 25A/AC250 V, 3~48VDC
W
°
°
°
W
TT-10
RAS-13NKP-HX, RAS-10NKP-HX)
4-4. Outdoor Unit (RAS-13N2A-E, RAS-13N2AX, RAS-12NAX-V)
No. Parts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor
PH225X2C-4FT
Winding resistance (W) C-R C-S
(at 20 C) 2.35 3.22
Output (Rated) 30 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
2 Fan motor (for outdoor)
HF-240-30B
Winding resistance (W) Red-Black White-Black
(at 20 C) 245 or 237 388 or 380
3
Running capacitor
DS451155NPQB AC 450 V, 1.5µ
°
°
4
Running capacitor
RS44B356U0125S AC 440 V, 35 F
(for compressor)
m
WLF-240-30A
or