– 31 –
8-6. Others
8-6-1. Gas Leak Test
Fig. 8-6-2
8-6-3. Auto Restart Setting
This product is designed so that, after a power failure,
it can restart automatically in the same operating mode
as before the power failure.
Information
The product was shipped with Auto Restart func-
tion in the off position. Turn it on as required.
<How to set the Auto Restart>
Press and hold down the TEMPORARY button for
about 3 seconds. After 3 seconds, the electronic
beeper makes three short beeps to tell you the Auto
Restart has been selected.
To cancel the Auto Restart, follow the page 16,17.
TEMPORARY
TEMPORARY
button
Fig. 8-6-1
Check the flare nut connections, valve stem cap
connections and service cap connections for gas
leak with a leak detector or soap water.
8-6-2. Test Operation
To switch the TEST RUN (COOL) mode, press TEM-
PORARY button for 10 sec. (The beeper will make a
short beep.)
Flare nut connections (indoor unit)
Electric parts
cover
Flare nut
connections
(Outdoor unit)
A
B
C
D
Valve stem cap
connection
Service cap
connection
Valve stem cap
connection