− 18 −
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1 Reactor
L = 10mH, 16A
2
Outdoor fan motor DC140V, 43W
3
Suction temp. sensor (TS sensor)
10kΩ (25°C)
4 Discharge temp. sensor (TD sensor)
62kΩ (20°C)
5
Outside air temp. sensor (TO sensor)
10kΩ (25°C)
6
Heat exchanger temp. sensor (TE sensor)
10kΩ (25°C)
7
Terminal block (5P)
30A, AC600V
9 COIL FOR P.M.V. DC12V
10 Coil for 4-way valve AC220-240V
CAM-MD12TCTH-5
SQ
Compressor 3-phases 4-poles 750W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA108X1C-23FZ
Parts name Model name Rating
CH-57 x 2 PCS
ICF-140-43-4R
FILE NO. SVM-13027
No. Parts name Type Specifications
ICE-340-30-4
DC 340V, 30W
2 Room temp. sensor (TA-sensor) ( - ) 10kΩ at 25°C
3 Heat exchanger temp. sensor (TC-sensor) ( - ) 10kΩ at 25°C
4 Louver motor 24BYJ48-HTP Output (Rated) 1W, 16 poles, DC12V
1
Fan motor
(for indoor)