7-2. Operation Data
<Coolin
>
Tempeature Model name Standard Heat exchanger Indoor Outdoor Compressor
condition(°C) RAS- pressure pipe temp. fan mode fan mode revolution
Indoor Outdoor P (MPa) T1 (°C) T2 (°C) (rps)
27/19 35/- 167SKV-E5 0.7 to 0.9 10 to 12 40to 42 High High 89
16EKV-EE 0.7 to 0.9 10 to 12 40 to 42 High High 89
<Heating>
Tempeature Model name Standard Heat exchanger Indoor Outdoor Compressor
condition(°C) RAS- pressure pipe temp. fan mode fan mode revolution
Indoor Outdoor P (MPa) T1 (°C) T2 (°C) (rps)
20/- 7/6 167SKV-E5 2.5 to 2.7 44 to 46 0 to 3 High High 86
16EKV-EE 2.5 to 2.7 44 to 46 0 to 3 High High 86
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m