– 4 –
FILE NO. SVM-06005
MODEL
RAS-18NKHD-E5 RAS-18NKD-E5 RAS-18NKDX5
RAS-18NAH-E RAS-18NA-E RAS-18N2AX
ITEM Cooling Heating Cooling Cooling
Capacity kW
220 V 240 V 220 V 240 V
220 V 240 V 220 V 240 V
5.05 5.05 5.80 5.90 5.20 5.25 5.20 5.25
Phase 1∅
Power source V 220 – 240
Hz 50
Power consumption W
1920 2040 1800 1950
1910 1990 1910 1990
Power factor % 95 88 94 86 92 85 92 85
Running current A 0.3
/ 0.3/ 0.3/ 0.3/
0.3/9.1 0.3/9.40 0.3/9.1
5 0.3/9.40
Indoor/Outdoor 8.9 9.4 8.4 9.2
Moisture removal lit/h 2
Noise
Indoor (H/M/L) dB 44/42/39/37/35
Outdoor (220 – 240 V) dB 52-53 53-54 51 52 51 52
Refrigerant
Name of refrigerant R22
Rated amount kg 1.53 1.00
Refrigerant control Capillary tube
Gas side size
mm
∅12.7
Connection type Flare connection
Liquid side size
mm
∅6.35
Interconnection Connection type Flare connection
pipe Maximum length
m
15*
1
(One way) 20*
2
Maximum height
m8
difference
INDOOR UNIT RAS-18NKHD-E5 RAS-18NKD-E5 RAS-18NKDX5
Height mm 298
Dimensions Width mm 998
Depth mm 220
Net weight kg 14
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 900 900 900
Air volume Medium fan m
3
/h 650 700 650
Low fan m
3
/h 530 570 530
Fan motor output W 30
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-18NAH-E RAS-18NA-E RAS-18N2AX
Depth mm
Net weight kg 43
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h
2350
2450
2350
2450
Fan motor output W
42
Compressor
Model
Output W 1500
Safety device IOL, Td Sensor IOL
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 –10 ~ 24
Starting current A
Height mm
Dimensions Width mm
PH340X3C-4KT1
42
45
550
780
290
550
780
290
2350 2450 2450
2550
1500
Note: * 1 Charge less pipe
* 2 Maximum pipe
44/42/39/37/35
41
21~43