– 3 –
FILE NO. SVM-06005
MODEL
RAS-24NKD-E5
RAS-24NKDX5
RAS-24N2AX
ITEM Cooling Cooling
Capacity kW
220 V 240 V 220 V 240 V
6.40 6.45 6.40 6.45
Phase 1∅
Power source V 220 – 240
Hz 50
Power consumption W 2350 2440 2350 2440
Power factor % 99 90 99 90
Running current A
0.3/10.5 0.3/11.0 0.3/10.50 0.3/11.0
Indoor/Outdoor
Starting current A 67
Moisture removal lit/h 2.7
Noise
Indoor (H/M/L) dB 45/43/41/39/37
Outdoor (220 – 240 V) dB 56-57
Refrigerant
Name of refrigerant R22
Rated amount kg
Refrigerant control Capillary tube
Gas side size
mm
∅15.88
Connection type Flare connection
Liquid side size
mm
∅6.35
Interconnection Connection type Flare connection
pipe Maximum length
m
15*
1
(One way) 25*
2
Maximum height
m10
difference
INDOOR UNIT RAS-24NKD-E5
RAS-24NKDX5
Height mm 298
Dimensions Width mm 998
Depth mm 220
Net weight kg 14
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 900
Air volume Medium fan m
3
/h 750
Low fan m
3
/h 600
Fan motor output W 30
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT
RAS-24NA-E
RAS-24N2AX
Height mm 715
Dimensions Width mm 780
Depth mm 290
Net weight kg
52
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 2400 2550 2400 2550
Fan motor output W 42
Compressor
Model
Output W
Safety device IOL
Louver type Automatic louver
Usable outdoor temperature range °C
1. SPECIFICATIONS
RAS-24NA-E
1.68
PH400X3CS-4KT1
1800
Note: * 1 Charge less pipe
* 2 Maximum pipe
21 ~ 43