FILE NO. SVM-06009
4-5. Outdoor Unit (RAS-24N2AX-T)
No. Parts name Type Specifications
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
1 Compressor PH400X3CS-4KT1 Winding resistance (Ω ) C-R C-S
(at 20 °C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 − 240 V, 50 Hz
Winding resistance (Ω ) Red-Black White-Black
2 Fan motor (for outdoor)
(at 20 °C)
128 126
FG-240-42A
AC 440 V, 50µF
1.13
2.10
3
Running capacitor
451305L
AC 450 V, 3.0µF
(for fan motor)
RS44B506U0218S
4
5 Magnetic contactor
A35
220 − 240 V, 50 Hz
Running capacitor
(for compressor)
− 13 −