FILE NO. SVM-06009
5-8. RAS-18NKPX-T / RAS-18N2AX-T
Indoor unit
Cross flow fan
Compressor
Condenser
Propeller fan
Outdoor unit
PH290X2C-4FT1
O.D.:15.88 mm O.D.:6.35 mm
Packed valve
(15.88)
Packed valve
(6.35)
T
P
Refrigerant
R22 1.50 kg
Evaporator
0.39 m
(Connecting pipe)
15.88
0.49 m
(Connecting pipe)
6.35
Mark ( ) means check points of Gas Leak
Capillary tube
2.0x1000 s
Accumulator
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.52 11.0 High 27/19 35/24
Cooling High temperature 0.62 14.7 High 32/23 43/26
Low temperature 0.38 3.0 Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure
P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe
T
(°C)
16